CONTROL SYSTEM
11-14
Revision 0
Service Manual – WNG DCI
11.12.2
Outdoor Unit Controller
JP9 JUMPER LAYOUT
Reserved
(PIN
9)
ODU3
(PIN 7)
ODU2
(PIN 5)
ODU1
(PIN 3)
ODU0
(PIN 1)
GND
(PIN 10)
GND
(PIN 8)
GND
(PIN 6)
GND
(PIN 4)
GND
(PIN 2)
ODU MODEL SELECTION
ODU3
ODU2
ODU1
ODU0
ODU Model
OFF
OFF
OFF
OFF
Reserved
OFF
OFF
OFF
ON (PIN1 & PIN2)
A (DCI 25)
OFF
OFF
ON (PIN3 & PIN4)
OFF
B (DCI 35)
OFF
OFF
ON (PIN3 & PIN4)
ON (PIN1 & PIN2)
C (DCI 50)
OFF
ON (PIN5 & PIN6)
OFF
OFF
D
OFF
ON (PIN5 & PIN6)
OFF
ON (PIN1 & PIN2)
E (Duo)
OFF
ON (PIN5 & PIN6)
ON (PIN3 & PIN4)
OFF
F
OFF
ON (PIN5 & PIN6)
ON (PIN3 & PIN4)
ON (PIN1 & PIN2)
G
ON (PIN7 & PIN8)
OFF
OFF
OFF
H
ON (PIN7 & PIN8)
OFF
OFF
ON (PIN1 & PIN2)
I
ON (PIN7 & PIN8)
OFF
ON (PIN3 & PIN4)
OFF
J
ON (PIN7 & PIN8)
OFF
ON (PIN3 & PIN4)
ON (PIN1 & PIN2)
K
ON (PIN7 & PIN8)
ON (PIN5 & PIN6)
OFF
OFF
L
ON (PIN7 & PIN8)
ON (PIN5 & PIN6)
OFF
ON (PIN1 & PIN2)
M
ON (PIN7 & PIN8)
ON (PIN5 & PIN6)
ON (PIN3 & PIN4)
OFF
N
ON (PIN7 & PIN8)
ON (PIN5 & PIN6)
ON (PIN3 ? PIN4)
ON (PIN1 & PIN2)
O
11.13
Test Mode
11.13.1
Entering Test Mode
System can enter Test mode in two ways:
Automatically when the following conditions exists for 30 minutes continuously:
Mode
l, Set point 16, Room temper
= Coo
=
ature = 27±1, Outdoor temperature = 35±1
Or
Mode = Heat, Set point = 30, Room temperature = 20±1, Outdoor temperature = 7±1
Manually when entering diagnostics with the following settings:
Mode = Cool, Set point = 16
Mode = Heat, Set point = 30
5HYLVLRQ<
Summary of Contents for ONG 25 DCI INV
Page 59: ...AUTO...
Page 60: ......
Page 68: ......
Page 69: ......
Page 70: ...1 AUTO...
Page 71: ...2 9 10 11 12 13 14 15 AUTO 1 2 3 4 5 6 7 8 16 17 18...
Page 72: ...3...
Page 73: ...4...
Page 74: ...5 COOL ESF EN RESET HEAT MODE F A PWR ESP PWR...
Page 75: ...6...
Page 76: ...7 AUTO AUTO...
Page 77: ...8...
Page 78: ...9...
Page 79: ...10...
Page 80: ...11...