OP RATING CURVES
E
Service Manual – WNG DCI
6-3
6.2
Model: WNG 35 DCI
6.2.1
Cooling – Test Mode
500
600
700
800
900
1000
1100
1200
1300
1400
10
15
20
25
30
35
40
45
S
uct
io
n
P
ressur
e
[kP
a]
22/15
24/17
27/19
29/21
32/23
Suction Pressure VS. Outdoor Temp'
Indoor DB/WB
Temp.
Outdoor Temp.(°C DB)
1000
1250
1500
1750
2000
2250
2500
2750
3000
3250
3500
3750
4000
10
15
20
25
30
35
40
45
D
isch
ar
ge
P
ressur
e
[kPa]
22/15
24/17
27/19
29/21
32/23
Discharge Pressure VS. Outdoor Temp'
Indoor DB/WB
Temp.
Outdoor Temp.(°C DB)
5HYLVLRQ<
35(6685(&859(6
Summary of Contents for ONG 25 DCI INV