ELECTRICAL DATA
Service Manual – WNG DCI
Revision 0
7-1
7. ELECTRICAL
DATA
7.1 Single
Phase
Units
model
WNG 25
WNG 35
Power Supply
1 PH, 220-240 VAC, 50Hz
Connected to
Indoor
Maximum Current
10 A
Inrush Current
(a)
35 A
Starting Current
(b)
10 A
Circuit breaker
16 A
Power supply wiring no. x cross section
3 X 1.5 mm
2
Interconnecting cable no. x cross section
4 X 1.5 mm
2
(a) Inrush current is the current when power is up (charging the DC capacitors
at outdoor unit controller).
(b) Starting current is the current when starting the compressor.
NOTE
Power wiring cord should comply with local lows and electrical
regulations requirements.