CONTROL SYSTEM
Service Manual – WNG DCI
Revision 0
11-1
11.
CONTROL SYSTEM
11.1
General Functions and Operating Rules
The DCI software is fully parametric.
All the model dependent parameters are shown in Blue color and with Italic style [
parameter
].
The parameters values are given in the last section of this control logic chapter of the service
manual.
11.1.1
System Operation Concept
The control function is divided between indoor and outdoor unit controllers. Indoor unit is the
System ‘Master’, requesting the outdoor unit for cooling/heating capacity supply. The outdoor unit is
the system
nless it enters into a protection mode
'Slave’ and it must supply the required capacity
avoiding it from supplying the requested capacity.
The capacity request is transferred via indoor to outdoor communication, and is represented by a
parameter called ‘NLOAD’. NLOAD is an integer number with values between 0 and 127, and it
represents the heat or cool load felt by the indoor unit.
11.1.2
Compressor Frequency Control
11.1.2.1 NLOAD setting
The NLOAD setting is done by the indoor unit controller, based on a PI control scheme.
The actual NLOAD to be sent to the outdoor unit controller is based on the preliminary LOAD
calculation, the indoor fan speed, and the power shedding function.
NLOAD limits as a function of indoor fan speed:
Indoor Fan Speed
Maximum NLOAD Cooling
Maximum NLOAD Heating
Low
Max NLOADIF1C
127
Medium
Max NLOADIF2C
127
High
Max NLOADIF3C
127
Turbo
Max NLOADIF4C
127
Auto
Max NLOADIF5C
127
NLOAD limits as a function of power shedding:
Mode
Power Shedding OFF
Power Shedding ON
Cool
No limit
Nominal Cooling
Heat
No limit
Nominal Heating
11.1.3
Target Frequency Setting
The compressor target frequency is a function of the NLOAD number sent from the indoor
controller and the outdoor air temperature.
Basic Target Frequency Setting:
NLOAD
Target Frequency
127
Maximum frequency
10 < NLOAD < 127
Interpolated value between minimum and maximum frequency
10
Minimum frequency
0
Compressor is stopped
5HYLVLRQ<
Summary of Contents for ONG 25 DCI INV
Page 59: ...AUTO...
Page 60: ......
Page 68: ......
Page 69: ......
Page 70: ...1 AUTO...
Page 71: ...2 9 10 11 12 13 14 15 AUTO 1 2 3 4 5 6 7 8 16 17 18...
Page 72: ...3...
Page 73: ...4...
Page 74: ...5 COOL ESF EN RESET HEAT MODE F A PWR ESP PWR...
Page 75: ...6...
Page 76: ...7 AUTO AUTO...
Page 77: ...8...
Page 78: ...9...
Page 79: ...10...
Page 80: ...11...