12-32
CONTROL SYSTEM
Revision Y05-01
Service Manual - COMPACT
12.15
Clock Random Delay From 0 to 2.5 seconds
0 = Clock Switch Open
1 = Clock Switch close
The Clock is activate according to the following table:
A/C STATE
(
before clock is changed)
CLOCK STATE
(
before clock is changed)
CLOCK ACTION
(clock is changed)
A/C NEW STATE
(after clock is changed)
ON
1
0
OFF
OFF
0
1
ON
OFF by
interrupt
(1)
1
0
OFF
ON by
interrupt
(1)
0
1
ON
Notes :
1.
Clock can be interrupted by :
•
R/C - POWER ON/OFF Push-button.
•
R/C - TIMER.
•
R/C - SLEEP.
•
A/C - MODE SWITCH.
2.
Any change in the CLOCK level during the first 6 sec after the system
Reset is ignored.