5-6
PERFORMANCE DATA
Revision Y05-01
Service Manual - COMPACT
5.4.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL (
q
C)
15 20 25
ENTERING AIR
WB OU COIL (
q
C)
TH PI TH PI TH PI
-10
1.40
0.74
1.34
0.79
1.29
0.83
-7
1.50
0.76
1.45
0.80
1.40
0.85
-2
1.60
0.77
1.54
0.82
1.49
0.86
2
1.94
0.81
1.86
0.86
1.78
0.91
6
2.74
0.87
2.66
0.93
2.57
0.99
10
2.98
0.92
2.90
0.98
2.82
1.05
15
3.22
0.96
3.14
1.03
3.06
1.10
20
3.39
0.99
3.31
1.07
3.22
1.15
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.5
Capacity Correction Factor Due to Tubing Length
5.5.1 Cooling
TOTAL TUBING LENGTH
3m
7.5m
10m 12m 20m 25m 30m 40m 50m
1.03
1
0.978
0.961 --- --- --- --- ---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
5.5.2 Heating
TOTAL TUBING LENGTH
3m
7.5m
10m 12m 20m 25m 30m 40m 50m
1.05
1
0.981
0.965 --- --- --- --- ---
*
Minimum recommended tubing length between indoor and outdoor units is 3m.
Summary of Contents for CON 12
Page 104: ...15 2 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual COMPACT...
Page 105: ...15 3 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual COMPACT...
Page 106: ...15 4 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual COMPACT...
Page 107: ...15 5 OPTIONAL ACCESSORIES Revision Y05 01 Service Manual COMPACT...
Page 110: ...AIR CONDITIONER SPLIT WALL MOUNTED PROGRAMMING AND OPERATING...
Page 128: ......
Page 129: ......