Operation
Parameter listing
24. 6.
5
Multi In AD 2
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Flue gas damper feedback
8 = Pressure Switch
0 - 8
0
24. 6.
6
Multi In AD 3
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Flue gas damper feedback
8 = Pressure Switch
0 - 8
0
24. 6.
7
Multi In AD 4
0 = None
1 = Room thermostat HC1
2 = Room thermostat HC2
3 = Room thermostat HC3
4 = 0-10V input request
5 = External operating mode changeover HCs+DHW
6 = Heat generation lock
7 = Flue gas damper feedback
8 = Pressure Switch
0 - 8
0
24. 7
Configurable Inputs-Outputs 2
24. 7.
0
Multi Out HV
0 = None
1 = System pump
2 = HC1 Pump
3 = Circulating pump
4 = DHW intermediate circuit pump
5 = BUF filling pump
6 = Storage tank transfer pump
7 =Heat gen shutoff valve
8 = Heat request
0 - 8
1
Menu
Submenu
Parameter Name
Description
Range
Factory
settings