e
Flow temperature 35°C
Flow temperature 45°C
Flow temperature 55°C
Air inlet temperature (°C)
Q
h
P
el
HEATING CAPACITY
External air temperature
°C
-15
-10
-7
2
7
10
15
20
Outlet water temperature
°C
35
Heating capacity
kW
4.41
4.98
5.28
6.36
8.64
9.73
11.91
14.03
Power consumption
kW
1.64
1.67
1.70
1.72
1.86
1.89
2.00
2.10
COP
2.69
2.98
3.10
3.69
4.66
5.16
5.96
6.68
Outlet water temperature
°C
45
Heating capacity
kW
4.45
5.03
5.33
6.43
8.70
9.82
12.03
14.17
Power consumption
kW
1.97
2.01
2.05
2.07
2.27
2.26
2.40
2.52
COP
2.26
2.51
2.61
3.11
3.83
4.34
5.02
5.62
Outlet water temperature
°C
55
Heating capacity
kW
-
4.45
5.03
6.51
8.27
9.13
9.92
10.71
Power consumption
kW
-
2.38
2.43
2.57
2.75
2.86
2.82
2.86
COP
-
1.87
2.07
2.53
3.01
3.19
3.52
3.74
15
Summary of Contents for AEROTOP G
Page 28: ...Installation Delivery to installation site 2 3 1 n 17 4x 8x M10 4x 4x 28...
Page 29: ...Installation Delivery to installation site 29...
Page 31: ...Installation Hydraulic connections assembly instructions 3 1 n 3 1 4 2x n 46 1 x 2 1 4 10 x 31...
Page 32: ...Installation Hydraulic connections assembly instructions 4 7 5 8 4x 1 4 6 2 x 32...
Page 36: ...Installation Instruction for the installation of control unit black wire CL 5 4 36...
Page 57: ...Notes 57...
Page 58: ...Service www elco net...