9 212V VISION SYSTEM
ELBO CONTROLLI srl
SETHY SIX
Press this key to acquire the radius value detected for the tools’ table or to rapidly print a
label.
Press this key again to repeat the procedure.
Press this key to close the measurement function.
9.8.7 Radii and angles checking with mobile grid
When you only need a simple comparison to check angles and radii, you can visualize, along with the
fixed grid, an angular grid indicating the degrees or a circular grid indicating the radius.
Both functions will not be activated in autocollimation mode.
In the case of an angular grid, collimate the axes of this grid with the tool’s profile to see
the inclination of a line (eg. Rakes, tools dislodgments, etc.).
Rotate using the cursor or by manually inserting the angle value to set with a maximum
precision of 1 centesimal degree on the numeric keyboard. Touch the value window to
display the keyboard.
Page 59 of 96
Point 5
collimation
Press to
capture
point 5
Calculated
radius value
Summary of Contents for SETHY SIX
Page 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL rev 1 0 05 13...
Page 15: ...6 PREPARATION AND INSTALLATION ELBO CONTROLLI srl SETHY SIX Page 15 of 96...
Page 16: ...6 PREPARATION AND INSTALLATION ELBO CONTROLLI srl SETHY SIX Page 16 of 96...
Page 38: ...8 PRELIMINARY OPERATIONS ELBO CONTROLLI srl SETHY SIX Page 38 of 96...
Page 39: ...8 PRELIMINARY OPERATIONS ELBO CONTROLLI srl SETHY SIX Page 39 of 96...
Page 65: ...9 212V VISION SYSTEM ELBO CONTROLLI srl SETHY SIX Page 65 of 96...
Page 93: ...18 ELECTRICAL DIAGRAM ELBO CONTROLLI srl SETHY SIX 18 ELECTRICAL DIAGRAM Page 93 of 96...
Page 94: ...19 PNEUMATIC DIAGRAM ELBO CONTROLLI srl SETHY SIX 19 PNEUMATIC DIAGRAM Page 94 of 96...