Power Spot 575IE II™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page
37
to head. Carefully pull back the socket assembly.
Gently remove the old lamp from it’s socket. If the old lamp has exploded be sure to
remove all of the old lamp fragments to prevent damage to the internal components.
Replace the lamp with an approved replacement type. Be sure to follow all the lamp
handleing procedures included with your new lamp. Never handle the new lamp with your
bare hands, the oils from your skin may damage the lamp. Always replace with the lamp
with a lamp that meets the orginal lamp specification, failure to do so may damage the unit
and will void your manufactures warranty.
Before reassembing the unit, be sure the new lamp is securely seated in lamp socket.
Reassemple the unit in reverse order.
Besure to reset the lamp running time in the “TIME“ menu. The lamp run time is designed
to function as lamp replacement reminder (see page 20).
Attention:
Be sure the lamp is securely seated in the lamp socket. Failure to comply with this
warning may cause excessive heat build-up that may cause the internal lens to crack.