Power Spot 575IE II™
©Elation Professionals® Los Angeles, Ca. - wwww.ElationLighting.com - Page
10
1.
Lens Assembly -
This high quality lens is a fully focusing. Focus the lens by
manually turning the lens in a clockwise or counter-clockwise direction until the
desired effect is achieved.
2.
DMX Input Jack –
This 3-Pin XLR jack is used to receive an incoming DMX signal.
3.
DMX Output Jack –
This 3-Pin XLR jack is used to send an outgoing DMX signal.
For best results this jack should be terminated if it is the last fixture in a DMX
daisy-chain (see termination on page 14).
4.
Microphone Sensitivity Adjustment Knob –
This knob is used to adjust the frequency
sensitivity of the internal microphone when operating in “audio” mode. When the
knob is turned counter-clockwise the unit is less sensitive to sound. When the
knob is turned clockwise the unit is more sensitive sound.
5.
Firmware Connection –
This connection is designed to be used solely by an
authorized technician to upgrade the operating software and to test the fixture.
6.
Internal Cooling Fan –
This fixture is equipped with two high-velocity variable
speed fans mounted in the base to aid in the cooling process. These fans are
designed to vary their velocity at different operating temperatures. When the
fixture reaches a predetermined internal operating temperature the fans function
at high speeds. The higher speeds provide better cooling associated with higher
operating temperatures during long use. When the fixture is operating at a lower
temperature the fans operate at low speed. Be sure to keep all vents clean,
blocked cooling vents can shorten lamp life and reduce the fixtures reliability.
For more information on the fan functions see page 23, section 3.9.7.
7.
Base –
The main base holds the majority of the electronics and logic boards. The
base also provides a means to securely mount the fixture to the floor or ceiling.
8.
Retaining Arm –
These arm hold the head in place and provide a means of tilt
movement. These arms also provide a conduit for all the electronics traveling
from the base to the head.
9.
Lamp Fuse Holder –
This housing holds a 8A/250V GMA fuse. Never defeat this
fuse, this fuse is designed to protect the lamp in the event of severer power
fluctuations. In the event of fuse failure, always be sure to replace this fuse with
an exact match unless otherwise instructed by an authorized Elation technician.
10.
Electronics Fuse Holder –
This housing holds a 1A/250V GMA fuse. Never defeat
this fuse, this fuse is designed to protect the electronics in the event of severer
power fluctuations. In the event of fuse failure, always be sure to replace this