BEA--250127-EN-09
19/22
ELMETA
®
MDS 50
LED signal lamp, red
303533
Amplifier VK 5020
312836
Set of insulating components for rollers
313556
The amplifiers VK 5020 are individually adjusted to the given met-
al detector. In case you have to exchange an amplifier, be sure to
specify on your spare parts order the ID-number or the order num-
ber indicated on the nameplate of the metal detector for which you
need the new amplifier. This information is required to allow us to
adjust the new amplifier to the values of the old one and thus to
guarantee its perfect function.
Be sure to disconnect the metal detector from the mains
while exchanging amplifier VK 5020.
The amplifier VK 5020 is located behind the cover plate of the
metal detector.
You must remove the plastic cover and the cover plate in oder to
replace the amplifier. Proceed as follows:
The plastic cover at the side of the metal detector is sealed with
Silikon (see figure to the left).
➜
Remove Silikon with a knife.
➜
Open fastening screws (M4 x 12) on the adapter plate and remove
plate very careflully.
➜
Detach very carefully the two lines to the indicator lights and the
ribbon line to the amplifier from the rear of the adapter plate. See
figure to the left. Now let the plate hang down
11. Spare parts
11.1 Exchange of amplifier
VK 5020
Plastic
cover
Fastening screws
Detach the lines