The field 

Number 

of the table shows the parameter number, the field 

Name 

the respective abridged designation. The field 

Default 

shows 

the standard settings, 

Min 

and 

Max 

are the acceptable limit values. 

The field 

Access 

specifies whether a parameter may just be read (R) 

or read and written (R/W). The field 

Explanation 

describes the func-

tion of the parameter. 

Number Name

Default Min

Max Access Explanation

0

edit device

X.X

X.1

X.F

R/W

Select equipment number (see block diagram)

1

edit group

X.X

0.X

7.X

R/W

Auswahl Gruppennummer (siehe Blockschaltplan)

2

reset settings

0

0

2

R/W

Works setting

0 = no function

1 = E+L basic settings

2 = preset internal value (default)

3

start service

0

0

199

R/W

Start a function

0 = no function

1 = reset controller

2 = save parameter 

4

version

-

-

-

R

Software version

5

sensor adjust

6

sensitivity

5

1

40

R/W

Sensitivity in mg Fe

1 = max. sensitivity

40 = min. sensitivity (chapter 3.4)

7

amplification

5

1

15

R/W

Amplification stages to adjust amplifier to the sensing 

head (to be modified only after consultation with E+L)

8

middle webspeed

130

3

199

R/W

Average web speed in m/min

In case of slow web speeds the value can be reduced 

(Filter for fast signals, chapter 7.2).

9

web speed adjust

(chapter 7.4)

10

measurement 

wheel

100

100

1999

R/W

circumference of measurement wheel in mm

11

imp./revolution

0

0

500

R/W

Pulse per revolution 

0 = no transducer connected

12

output 1 adjust

(chapter 7.3)

13

normal - invers

1

0

1

R/W

Output1

0 = 24 V ON at signal

1 = 24 V OFF at signal (works setting)

14

pulse time

0

0

19,9

R/W

Duration of output impulse in s

0 = reset via input or key RESET

value > 0 = time after which signal output 1 will be  

 

automatically reset

8. Parameters

8.1 Parameter listing MDS 50

Summary of Contents for elmeta mds 50

Page 1: ...3 2 Keys 5 3 3 Basic operation in setup mode 6 3 4 Setting the metal detector sensitivity 7 3 5 Instructions for daily use 8 4 Adapter plate 8 5 Assembly 10 6 Installation 12 7 Commissioning 13 8 Par...

Page 2: ...rior to mounting operation and maintenance Never touch the edges of moving webs Never touch live parts When mounting the metal detector the safety clearances stipulated by the locally applicable and p...

Page 3: ...sists of a probe and two side parts The open fabric width passes accross the probe The metal detector operator panel is located in one of the side parts The connections for the sup ply voltage CAN bus...

Page 4: ...ding on the web speed and the distance between the metal detector and fol low up machine devices 2 1 2 place digital display In normal operation the digital display indicates the metal detector sensit...

Page 5: ...the LED that had indicated the maximum value remains illuminated Then the LEDs to the left go on one after the other until only the green LEDs are illuminated All LEDs light up approx 60 sec during a...

Page 6: ...entire system Select expanded setup mode select device number X 5 then press and hold down the setup key now select parameter 3 using the increase value key Let the setup key go again and enter parame...

Page 7: ...increase in sensitiv ity disturbances in the operating voltage potential elect ro mag ne tic fields in the vicinity of the probe head probe head vibrations during operation metal residue in the web c...

Page 8: ...total length of the CAN bus line must not exceed 200 meters Both ends of the CAN bus line must feature a terminating resistor connector The LED indicates whether the CAN bus card in the metal detecto...

Page 9: ...such as calander rollers shearing tools or marking systems The signal output is only active when com bined with an incremental encoder for the web speed It is set depending on the web speed and the d...

Page 10: ...the metal particles to the probe head surface increases Typical sensitivity at 2 mg Fe Lengthwise Transverse Vertical Probe head surface Web Position of needle like metal particles 5 Assembly 5 1 Tra...

Page 11: ...use the rubber metal vibration damper supplied This is equally important when mount ing a center support Two metal detectors should be at least 3 meters apart Metal path rollers with a diameter of up...

Page 12: ...tector E L has a set of insulating components available See figure below and chapter on spares insulating Example set of insulating components for metal rollers Grounding strip 5 4 Installation 6 Inst...

Page 13: ...Commissioning points 7 2 to 7 4 should be performed when the web is at a standstill Changed parameter values are ad opted immediately The metal detector may be adjusted to lesser speeds on application...

Page 14: ...he incremental encorder per revolution max 500 Select parameter 16 and set the signal output operating mode 0 24 V ON with signal 1 24 V OFF with signal works set Select parameter 17 and enter the dis...

Page 15: ...ntroller 2 save parameter 4 version R Software version 5 sensor adjust 6 sensitivity 5 1 40 R W Sensitivity in mg Fe 1 max sensitivity 40 min sensitivity chapter 3 4 7 amplification 5 1 15 R W Amplifi...

Page 16: ...low 4 temperature too high 85 5 sensor system defect 6 system compensation oscillates 7 system compensation too little 8 system compensation too big 23 history number 0 0 50 R W Number of system error...

Page 17: ...s for test and service purposes to be modified only after consultation with E L 49 DC level 64 20 255 R W DC signal level for automatic compensation 50 DC delta 8 4 100 R W DC signal window for automa...

Page 18: ...ctuates by more than 10 con nect the metal detector to another power circuit Check the electrical leads for defects Check whether the switching on of another machine has triggered the signal If this i...

Page 19: ...e sure to disconnect the metal detector from the mains while exchanging amplifier VK 5020 The amplifier VK 5020 is located behind the cover plate of the metal detector You must remove the plastic cove...

Page 20: ...ier no jerks to make sure that the plug does not get damaged Use an appropriate tool Open fastening scsrews M3 x 6 at amplifier and remove ampli fier Make sure that no line gets damaged See figure to...

Page 21: ...DC incl residual ripple Residual ripple max 5 Input power max 36 W length dependent Signal inputs reset path sensor Voltage 20 to 30 V DC Current 6 to 10 mA Input resistance 3 kOhms Frequency 6 kHz 10...

Page 22: ...burg GERMANY Phone 49 0 821 2435 0 Internet http www erhardt leimer com E mail info erhardt leimer com Power supply CN 4002 Voltage 100 240 V AC 50 60 HZ Current 2 3 A Power 60 W Technical data subjec...

Reviews: