16/22
BEA--250127-EN-09
ELMETA
®
MDS 50
15
output 2 adjust
(chapter 7.4)
16
normal - invers
1
0
1
R/W
Output 2
0 = 24 V ON at signal
1 = 24 V OFF at signal
17
distance
out 1, out 2
0
0
1999
R/W
Distance between metal detector and lift-off point in cm
Only in connection with a pulse transmitter,
Parameter 11 > 0
18
distance out 2 on
0
0
199
R/W
Distance for how long output 2 is set, in cm
Only in connection with a pulse transmitter,
Parameter 11 > 0
19
diagnostics
20
running time meter
0
0 65535
R
Running time in h
21
detected parts
0
0 32000
R
Number of detected metal particles
22
system error
0
0
499
R
Aktual system errorr
(will be displayed only as long as the error is actually
there. It will then be written into an error memory.
parameter 23 to 25)
Error code
..0 = no error
..1 = operational voltage too low
..2 = operational voltage too high
..3 = operational voltage/emitter voltage too low
..4 = temperature too high > 85°
..5 = sensor system defect
..6 = system compensation oscillates
..7 = system compensation too little
..8 = system compensation too big
23
history number
0
0
50
R/W
Number of system error in error memory
0 = most recent system error
50 = oldest system error
24
history error
xx
0
499
R
Error code at parameter 23
25
history time
xx
0.0 65535
R
Working hour at parameter 23
26
supply voltage
xx
0
100
R
Operational voltage in V
27
temperature
xx
0
100
R
Temperatur im Verstärker in °C
28
AC signal
xx
0
255
R
Signal phase relation
29
DC signal
xx
0
255
R
Signal amplitude
30
webspeed
xx
R
Web speed
Only in connection with a pulse transmitter,
Parameter 11> 0
31
autocal by ready
xx
0 32000
R
Auto - compensation during operation
32
testmode
Parameter for testing and service purposes,
o be modified only after consultation with E+L
33
testmode on-off
0
0
1
R/W
Test mode ON-OFF
0 = OFF
1 = ON
Parameter 34 - 43 can only be modified if test mode is
ON
34
amplification real
xx
1
100
R/W
Amplification in %
35
integration time
xx
1
100
R/W
Phase error integration time in %