When chronothermostat function is active, the temperature data will be followed by details on chronother-
mostat status separated by a comma:
When chronothermostat function is active, the chronothermostat data will be followed by details on boiler
status separated by a comma:
Note:
if chronothermostat is set to manual mode, the temperature can be set from keypad with decimals
and 0.3°C steps.
• R. P -> GPS position report
Using GPS position SMS report, users are able to get information on GPS positioning from any number in
the panel phone number list.
SMS text: “pos: LT XX.XX XXXXN/S, LN YY.YY YYYYE/W, DS Zm”
if there is the GPS Fix and the GPS localization service link has not been setup;
XX
= latitude in degrees and minutes (or only degrees according to setup)
YY
= longitude in degrees and minutes (or only degrees according to setup)
Z
= distance in meters from the reference coordinates (<???> when they have not been defined).
SMS text: “pos: LT XX.XX XXXXN/S, LN YY.YY YYYYE/W, DS Zm, GPS positioning service link”
if there is the GPS Fix and the GPS localization service link has been set, and the transmission of coordi-
nates together with the link is active.
SMS text: “NO GPS FIX”
when GPS Fix is absent.
• R. B -> External battery voltage report
The report SMS transmits information on voltage level of the battery that powers the panel when the battery
is used for vehicles and the MDPOWER24 module is used too.
Chronothermostat ON
-->>
chronothermostat is enabled and controls the
boiler
Chronothermostat XX degrees
-->>
chronothermostat is set to manual mode
(0°-49°C without decimals)
Chronothermostat OFF
-->>
chronothermostat is disabled and does not control
the boiler
Chronothermostat ANTIFREEZE
-->>
chronothermostat in antifreeze mode
Boiler ON
-->>
chronothermostat controls boiler ON status
Boiler OFF
-->>
chronothermostat does not control boiler ON
status
Boiler BLOCKED
-->>
chronothermostat controls boiler ON status but a
boiler failure has been detected