14
VILLEGGIO -
USER MANUAL
- 090060699
The message will be displayed for 15 seconds during which
the arming of system can be forced
as fol-
lows:
-
with code on keypad:
press OK.
-
with M4 key:
present M4 key or press OK on the keypad to which the reader is
connected.
-
with remote control device:
activate remote control again.
Note:
in case of arming denied and forced arming with M4 key, the red LED will blink fast during arming
procedure to indicate the forced command (in case of partial arming from I66 reader connected to
the onboard keypad, yellow LED will blink as well.)
4.9 Automatic forced arming
Forced arming becomes automatic in case of fault or ’no supervision’ event under the following conditions:
- system armed remotely via software application,
- system armed by system timer,
- system armed via SMS text.
4.10 Automatic forced arming denied
Automatic force arming will be denied in case of detector(s) in anomaly condition.
In such case, if the arming command was sent via SMS, the unit will promptly reply with the following mes-
sage:
< DISARMING DENIED >
4.11 Fast arming
This function allows to arm the unit without using a key or the user code.
For a sector fast arm follow the instructions in the following drawing:
NOTE: If a different sector key is pressed during the procedure, the armed sector will be modified.
If the fast arming is not confirmed with OK key, the procedure will be cancelled after 5 seconds.
Fast arming can be activated only for sectors not armed and not being armed; in addition, sectors must have
been associated to at least one user.
If you press the key of a sector that cannot be armed during the fast arming procedure, the procedure will
be stopped.
CONFIRM
THE COMMAND
EXIT TIME WILL ACTIVATE AND WILL
BE INDICATED BY THE CADENCED
BEEPING OF KEYPADS AT THE
REMOTE CONTROL SITES
PRESS THE KEY OF THE SECTOR TO BE
ARMED IN FAST MODE.
THE KEY WILL START BLINKING