Pellet burner GP xx sc 41
ERROR
CODE
INSCRIPTION
DISPLAYED ON THE
DISPLAY
ERROR DESCRIPTION
REMEDY
24
[ERROR: LOST FIRE]
[IN COMBUSTION]
Loss of lightness of photosensor
during work and unsuccessful
new ignition
Seek service assistance.
25
[ERROR: SCRAPER]
[OPERATION]
The board of the self-cleaning
mechanism is not working or
motor mechanism
Seek service assistance.
26
[ERR: SCRAP.STUCK]
[TURN OFF 5 MIN]
Self-cleansing mechanism is
blocked in an unknown situation
Seek service assistance.
27
[ERR: SCRAP.STUCK]
[OUTWARDS]
Self-cleansing mechanism is
blocked in forward motion
Seek service assistance.
28
[ERR: SCRAP.STUCK]
[INWARDS]
Self-cleansing mechanism is
blocked in backward motion
Seek service assistance.
29
[ERROR: SENSOR B]
[LOW TEMP]
The temperature sensor B has
measured value under 5
o
C
The circulation water is with
dangerously low
temperature and is possible
its freezing point.
Seek service assistance to
check the heating
installation.
30
[ERROR: SENSOR B]
[OVERHEAT]
The temperature sensor B
measured value over 95
o
C
Circulating water is with
dangerously high
temperature and possible
overheating of the heating
system and equipment.
Seek service assistance to
check the heating
installation.
31
[ERROR: SENSOR C]
[LOW TEMP]
The temperature sensor C has
measured value below 5
o
C
The circulation water is with
dangerously low
temperature and is possible
its freezing point.
Seek service assistance to
check the heating
installation.
32
[ERROR: SENSOR C]
[OVERHEAT]
The temperature sensor C has
measured value over 95
o
C
Circulating water is with
dangerously high
temperature and is possible
overheating of the heating
system and equipment.
Seek service assistance to
check the heating
installation.
33
[ERROR: FAN 2]
[ALWAYS ON]
Flue gases fan can not be
stopped, possible damage at the
controller exit
Seek service assistance.
34
[ERROR: FAN 2]
[STOPP]
Flue gases fan does not rotate
Seek service assistance.
35
[ERROR: FAN 2 RPM]
[]
Flue gases fan does not rotate
with the desired speed
Seek service assistance.