16. STANDING OFF
In the case compressor will be not to use for a prolonged time period, it is recommended to drain down the
condensate from pressure tank and the compressor put into operation for about 10 minutes with open valve
for condensate draining down (1) fig.8. Then switch off the compressor by switch (3) at pressure switch (2)
fig.7, close valve for condensate draining down and disconnect the appliance from mains.
17. LIQUIDATION OF THE APPLIANCE
• Disconnect the appliance from mains.
• Release air pressure in pressure tank by opening the valve for condensate drain down (1) fig.8
• Liquidate the appliance according to local valid regulations. Order the sorting and liquidation of waste in
specialized organization.
• Parts of the product after the end of its operating life do not have negative impact on environment.
18. INFORMATION ON REPAIRSERVICE
Guarantee and post-guarantee repairs are ensured by manufacturer or organizations and repairers denoted
by the supplier.
Warning !
Manufacturer reserves the right to make changes on the appliance that however will have no impact on
substantial characteristics of the appliance.
19. TROUBLESHOOTING
Prior the intervention to the appliance, it is necessary to reduce air pressure in air
chamber to zero and disconnect the appliance from mains.
Activities regarding troubleshooting can be performed only by qualified service expert.
FAILURE POSSIBLE
CAUSE
REMEDY
No voltage in pressure switch
Control of voltage in socket
Control of fuse – replace faulty one
Loosen terminal – tighten it
Control of power cord – replace faulty one
Compressor does not
start
Disconnected winding of a motor, damaged
thermal protection
Faulty capacitor
Seizure of piston or another rotary part
Pressure switch does not switch on
Replace motor, or re-wind it
Replace capacitor
Replace damaged parts
Control the function of pressure switch
Compressor often
switch on
Leakage of air from pneumatic distribution
system
Leaking check valve
Greater volume of condensed liquid in
pressure vessel
Control of pneumatic distribution system – seal
loosen join
Clean check, replace seals, replace check
valve
Drain out condensed liquid
Operation of
compressor is
prolonged
Leakage of air from pneumatic distribution
system
Worn-down piston ring
Contaminated filtration pad
Dirty filter in the dryer
Defective solenoid valve
Control of pneumatic distribution system –
seal loosen join
Replace worn-down piston ring
Replace contaminated pad with the new one
Change the inlet and outlet filter event. the
filling when to dirty or dusty
Repair or change the valve
Compressor is noisy
(knocking, metal
noises)
Damaged bearing of piston, piston rod,
bearing of motor
Loosen (cracked) crush element (spring)
Replace damaged bearing
Replace damaged spring
Dryer doesn´t dry
(condensing water in
the tank)
Devaluated or very polluted filling
Change the filling and filters
Summary of Contents for DK50 S
Page 2: ......
Page 3: ...DK 50 06 2008 3 NP DK50_2 OBSAH 4 CONTENTS 18 32 INHALT 47 SOMMAIRE 61 SPIS TRE CI 76 Ed 2 F...
Page 33: ...DK50 06 2008 33 NP DK50_2 1 CE CE 93 42 EEC 2 2 1 2 2 2 3...
Page 34: ...DK50 NP DK50_2 34 06 2008 3 CE 4...
Page 39: ...DK50 06 2008 39 NP DK50_2 3 MONZUN M1 10 4 KJF1...
Page 40: ...DK50 NP DK50_2 40 06 2008 9 5 C 40 C 70 6 10 10 1 5 X Y...
Page 45: ...DK50 06 2008 45 NP DK50_2 15 5 11 1 1 2 3 16 10 1 8 3 2 7 17 1 8 18 11...
Page 46: ...DK50 NP DK50_2 46 06 2008 19...
Page 95: ......