DK50
06/2008
- 21 -
NP-DK50_2
5. RANGE OF DELIVERY
Compressor - type: ...........................………………… DK50 Z / DK50-10 Z
.............1 pc
DK50 S / DK50-10 S
Installation, operation and maintenance manual ........ NP-DK50
......…...1 pc
Fuse T10A(230V).................................................... 038100005-000
………...2 pcs
T16A(110V).................................................... 038100007-000 .………..2 pcs
Applicable only for
: The compressor with air dryer
Dryer outlet filter - 4KB-650 ............…........................ 024000653-000
.............1 pc
6. TECHNICAL
DATA
DK 50 Z
DK 50 S
DK 50-10 Z DK50-10 Z/M DK 50-10 S DK50-10 S/M
Nominal voltage / (
*
)
frequency V / Hz
230 / 50
230 / 60
110 / 60
230 / 50
230 / 60
110 / 60
230 / 50
230 / 60
110 / 60
230 / 50
230 / 60
110 / 60
230 / 50
230 / 60
110 / 60
230 / 50
230 / 60
110 / 60
Efficiency of compressor at
over-pressure 5 bar
L.min
-1
70 70 70 70 70 70
Efficiency of compressor with
KJF-1 at over-pressure 5 bar
L.min
-1
70 70 70 - 70 -
Nominal current
at over-pressure 6 bar A
3,4
4,3
8,6
3,4
4,3
8,6
3,4
4,3
8,6
3,6
4,5
8,8
3,4
4,3
8,6
3,6
4,5
8,8
Motor performance
kW
0,55 0,55 0,55 0,55 0,55 0,55
Capacity of air chamber
Lit.
5 5 10 10 10 10
Working pressure of (
**
)
compressor aggregate
bar
4,5 – 6,0
4,5 – 6,0
4,5 – 6,0
4,5 – 6,0
4,5 – 6,0
4,5 – 6,0
Permitted operation pressure
of safety valve
bar
8,0 8,0 8,0 8,0 8,0 8,0
Noise level
L
pfA
[dB]
≤
65
≤
45
≤
65
≤
65
≤
45
≤
45
Mode of operation of
compressor
continual
S 1
intermittent
S 3 – 50%
continual
S 1
intermittent
S 3 – 60 %
intermittent
S 3 – 50%
intermittent
S 3 – 50%
Dimensions of compressor
w x l x h mm
290x430x490 380x525x575 330x430x530 330x580x570 420x525x620 420x675x620
Weight of compressor
kg
34 46 36 48 49 64
Weight of compressor in
cardboard kg
36 48 38 51 51 67
Level of drying of compressor
with dryer atmospheric
condensation point
- - -
-20°C
-
-20°C
Version according to
EN 60 601-1(STN EN 60
601-1)
appliance of type B, class I.
Notices:
* When ordering, state the version of compressor
**
Different range of pressure to consulted with contractor
- Weight of kompressor with KJF-1increase about 3kg
Climatic conditions during storage and transport
Temperature
–25°C to +55°C, 24 h to +70°C
Relative air humidity
10% to 90 % (no condensation)
Climatic operation conditions
temperature
+5°C to +40°C
Relative air humidity
70%
Summary of Contents for DK50 S
Page 2: ......
Page 3: ...DK 50 06 2008 3 NP DK50_2 OBSAH 4 CONTENTS 18 32 INHALT 47 SOMMAIRE 61 SPIS TRE CI 76 Ed 2 F...
Page 33: ...DK50 06 2008 33 NP DK50_2 1 CE CE 93 42 EEC 2 2 1 2 2 2 3...
Page 34: ...DK50 NP DK50_2 34 06 2008 3 CE 4...
Page 39: ...DK50 06 2008 39 NP DK50_2 3 MONZUN M1 10 4 KJF1...
Page 40: ...DK50 NP DK50_2 40 06 2008 9 5 C 40 C 70 6 10 10 1 5 X Y...
Page 45: ...DK50 06 2008 45 NP DK50_2 15 5 11 1 1 2 3 16 10 1 8 3 2 7 17 1 8 18 11...
Page 46: ...DK50 NP DK50_2 46 06 2008 19...
Page 95: ......