DK50 9x4VRT/M
10/2018
NP-DK50-9x4VRTM_ED-EN-2_10-2018
- 29-
Compressor module ambient
temperature exceeds the limit.
WARNING - high ambient temperature alarm.
The display flashes orange.
This alarm appears if the ambient temperature
exceeds the 40°C limit for at least 30 seconds.
The air pumps operate normally.
The display otherwise shows the current
ambient air temperature
The alarm clears when the temperature drops
below the limit.
The compressor
supplies
air to the
compressed air system as needed and
without restriction.
Compressor module internal
temperature exceeds the limit.
WARNING - high temperature alarm inside an
enclosed compressor. The display flashes
orange.
This alarm appears if the temperature inside
the enclosed compressor module exceeds the
70°C limit for at least 30 seconds. The air
pumps operate normally.
Note: The internal temperature monitoring
function is not included for unenclosed
compressors.
The display shows the current temperature
inside the enclosed compressor module
The alarm clears when the temperature drops
below the limit.
The compressor
supplies
air to the
compressed air system as needed and
without restriction.
Low pressure alarm during compressor
start-up.
SIGNALING - Low pressure alarm during
compressor start-up. The display flashes
orange
PRESSURE - current pressure in the system
HOURS RUN – operating hours
TIME –TO –GO MN - time to next service
interval
The information on the display automatically
disappears once the air pressure is above 5
bar.
The compressor
supplies
air to the
compressed air system as needed and
without restriction.
Low pressure alarm at elevated
compressed air demand.
SIGNALING – low pressure alarm at elevated
compressed air demand. The display flashes
orange
PRESSURE - current pressure in the system
The display automatically disappears once the
air pressure is above 5 bar.
Summary of Contents for DK50 9x4VRT/M
Page 1: ...DK50 9x4VRT M User manual EN...
Page 2: ...October 2018 Z_2195 2018 Chap 3 pgs 5...
Page 22: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 22 10 2018 Fig 13 Fig 14 Fig 15 Cable bridge...
Page 42: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 42 10 2018 ANNEX 22 MAPPING PARAMETERS...
Page 43: ...DK50 9x4VRT M 10 2018 NP DK50 9x4VRTM_ED EN 2_10 2018 43...