INSTALLATION
01/2020
-21-
NP_AD500-2250-1_01_2020
Risk of fire or explosion.
The dryer is exclusively designed for treatment of air without content of oil and
explosive or chemically unstable substances. The dryer must not be used to treat
aggressive gases.
Risk of damage to pneumatic components.
The maximum inlet air pressure is 10 Bar(g).
Risk of device overheating and damage to pneumatic components.
The maximum inlet air temperature is 150°C.
A non-return valve must be installed on the dryer outlet to permit venting the
dryer (during service) without the need to vent pressure from the distribution
system downstream of the dryer.
13.3. Condensate drain
Connect a hose to the outlet (1) from the
automatic condensate drain (2) to drain
piping or to the provided collection vessel
(Fig. 7).
A silencer is recommended when
connecting directly to drain piping.
Fig. 7: Condensate drain
14. ELECTRICAL CONNECTION
The product is equipped with a grounded plug. Insert the mains plug into a rated mains socket.
Keep the socket easily accessible to ensure that in an emergency the device can be safely
disconnected from the mains.
Power distribution short circuit protection max.16 A.
Risk of electric shock.
it is necessary to follow all local electrotechnical regulations. The mains voltage
and frequency must comply with the data stated on the device label.
Risk of fire and electric shock.
Electrical cable must not be in contact with hot dryer components and
connecting hoses.
Summary of Contents for AD2250
Page 1: ...AD500 2250 User manual N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 5 OBSAH 46...
Page 14: ...PRODUCT DESCRIPTION NP_AD500 2250 1_01_2020 14 01 2020 Valve switching diagram ECONOMY mode...
Page 16: ...PRODUCT DESCRIPTION NP_AD500 2250 1_01_2020 16 01 2020 Fig 2 Dryer AD1500 Fig 3 Dryer AD2250...
Page 57: ...POPIS V ROBKU 01 2020 57 NP_AD500 2250 1_01_2020 Obr 2 Su i AD1500 Obr 3 Su i AD2250...
Page 90: ......
Page 91: ......