PRODUCT DESCRIPTION
01/2020
-11-
NP_AD500-2250-1_01_2020
Name
Filter
specification
Dryer
Article number
FILTER KIT FS 49AH
b)
AC/HC/0,01um
AD-500-1250 E,S
447000001-179
FILTER KIT FS 50AH
b)
AC/HC/0,01um
AD-1500-2250 E,S
447000001-180
FILTER KIT FS 51AH
b)
AC/HC/0,01um
AD-500-1250 C
447000001-169
FILTER KIT FS 52AH
b)
AC/HC/0,01um
AD-1500-2250 C
447000001-170
FILTER KIT FS 49S
a)
0,01um
AD-500-1250 E,S
447000001-171
FILTER KIT FS 50S
a)
0,01um
AD-1500-2250 E,S
447000001-172
FILTER KIT FS 51S
a)
0,01um
AD-500-1250 C
447000001-173
FILTER KIT FS 52S
a)
0,01um
AD-1500-2250 C
447000001-174
FILTER KIT FS 49F
a)
1um
AD-500-1250 C
447000001-175
FILTER KIT FS 50F
a)
1um
AD-1500-2250 C
447000001-176
FILTER KIT FS 51F
a)
1um
AD-500-1250 E,S
447000001-177
FILTER KIT FS 52F
a)
1um
AD-1500-2250 E,S
447000001-178
a)
Accessory “Filter kit FS 49S-FS 52S” and “Filter kit FS 49F-FS 52F” filter assemblies contain a bracket and
a 1 or 0,
01 µm particulate filter
b)
The accessory “Filter kit FS 49AH-FS 52AH” filter assembly contains a bracket and a 0,01 µm particulate
filter with an AC (activated carbon) filter and HC (catalytic) filter.
8. PRODUCT FUNCTION
8.1.
Design and principle of operation
Dryer design
The AD model line of dryers consists of adsorption dryers based on
the PSA (“Pressure Swing
Adsorption”) method. Fig. 1. The dryer is composed of a compressed air cooler with fans (1),
condensate separator (13), inlet valve module (2), two chambers with replaceable cartridges filled
with adsorbent (3), outlet module (4) and control unit (5).
The inlet valve module is fitted with inlet (8 and 9) and regeneration (purge) (6 and 7) normally-
closed (NC) solenoid valves, which are used for cyclic chamber switching. Silencers (11) are
installed on the regeneration valves outlets. An outlet logic valve and purge orifices are installed in
the outlet module. The outlet module contains a dew point sensor in the “C” dryer versions.
Compressed air enters the equipment through the inlet (12) at the bottom of the cooler. The
compressed air outlet (17) is located in the output module.
The switch, power cord connector and control signal connector (e.g. from the compressor) are
placed from below at the front of the dryer. The RJ-45 Ethernet connector is located in the rear.
Principle of operation
Inlet air flows through the cooler and condensate separator into the valve module, where it is
directed into the active chamber with adsorbent, where the air is dried. The air then passes through
the built-in filters (see Fig. 1), outlet module and outlet filters (if the dryer is equipped accordingly)
to the outlet. A portion of the dry air (purge air) is directed into the second, regenerated chamber
from the outlet module through the purge orifices. The purge air with moisture removed from the
adsorbent is then released through the silencer. The chambers switch their functions cyclically.
Risk of high temperatures.
Placing air flow impediments upstream or downstream of the cooler is prohibited.
The temperature of internal and external parts of the equipment may rise to
hazardous levels.
Summary of Contents for AD2250
Page 1: ...AD500 2250 User manual N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 5 OBSAH 46...
Page 14: ...PRODUCT DESCRIPTION NP_AD500 2250 1_01_2020 14 01 2020 Valve switching diagram ECONOMY mode...
Page 16: ...PRODUCT DESCRIPTION NP_AD500 2250 1_01_2020 16 01 2020 Fig 2 Dryer AD1500 Fig 3 Dryer AD2250...
Page 57: ...POPIS V ROBKU 01 2020 57 NP_AD500 2250 1_01_2020 Obr 2 Su i AD1500 Obr 3 Su i AD2250...
Page 90: ......
Page 91: ......