General Safety Instructions
Eisfink Max Maier GmbH & Co. KG
11
3.6.5
Dangers due to electricity
Before each use, inspect the product, the connecting plug and electric cable for any visible signs
of damage.
The cable must be routed so that it cannot be squeezed or overheated.
The socket outlet must be easily accessible so that the unit can be disconnected from the power
supply at any time.
Compare the connection data on the type plate with the data of the electrical network before
connecting (voltage and frequency, power rating).
3.6.6
Risks due to power interruption possible
Possibility of malfunction after power interruption.
Disconnect the unit from the mains completely after a power failure.
Then switch back on.
3.6.7
Warnings concerning the use of the appliance by children
This appliance may be used by children over 12 and by persons with limited physical,
sensory and intellectual abilities or a lack of experience and/or knowledge if they are
supervised or if they were instructed in the safe use of the appliance and have understood
the resulting dangers.
When using the appliance with ‘accessories’, other risks may arise.
Children may not play with the appliance.
Cleaning and user maintenance may not be carried out by children without supervision.
3.6.8
Safety and monitoring devices
High-performance grease separator (100% flame propagation proof) with Cyclone
®
blade
profile (separation efficiency approx. 95%)
In addition to protection against electric shock and in order to ensure that the frames of
electrical equipment and any external conductive components are at an equal (or practically
equal) potential, the appliance must be connected to the potential equalisation system.
The connection of all conductive bodies (housing) of electrical equipment to an earthed
protective conductor and the main earthing bar is the basic principle for protection against
electric shock.
For variant with odour elimination using plasma technology:
Pressure sensor monitors the pressure conditions in the technical compartment; in the
event of a fault the plasma generator is switched off