INSTALLATION ON THE VEHICLE
22
The technical materials and information contained in this document are strictly confidential and the exclusive property of Advanced Microwave Engineering s.r.l.
These materials and information are intended solely for the purpose designated and may not be used otherwise.
It is not permitted to disclose or reproduce them in whole or in part without express written permission.
To connect the HUB, an UTP cable belonging to Cat. 5e or higher must be connected to one of the Sensors ports.
The CPU has 2 relays that can be controlled independently. There are 3 pins for each relay:
- NO | normally open
- C | common
- NC | normally closed.
The default configuration indicates that:
Relay 1
(RL1) remains active until the system detects one or more TAGs in the long-range
detection area, i.e. in pre-Warning.
Relay 2
(RL2) remains active until the system detects one or more TAGS in the short-range
detection area, i.e. in Warning.
The configuration of the relays can be modified from the advanced settings of the system (contact technical support for
help).
8.3.3
Connecting sensors
The sensors are connected to the HUB with 8 poles UTP cables. The maximum connection length is linked to the supply
voltage and the type of cable
AWG 26
AWG 24
12 V
3m
6m
24 V
25m
50m
Figure 1 Maximum length of the HUB sensor connection cables according to the type of cable and the power supply
The UTP cable must be connected to the J1 connector inside the sensor box with an RJ45 connector.