background image

EFKA Variocontrol V810/V820 

 

 

6  Operating Elements of the Control Panel V810 

 

 

 
 

Use insertable strip whose symbols correspond to the type of control. Pull out the standard insertable 
strip by using a tool (e.g. tweezers), if necessary, and insert the appropriate strip. 
See annex A. 

 

Functional Setting of the Pushbuttons 

 
Pushbutton P 

Recall or exit of programming mode 

Pushbutton E 

Enter button for modifications in the programming mode 

Push 

Increase of the value indicated in the programming mode 

Pushbutton - 

Decrease of the value indicated in the programming mode  

 
Pushbutton 1 

Start backtack SINGLE / DOUBLE / OFF or start stitch condensing 

Pushbutton 2 

End backtack SINGLE / DOUBLE / OFF or end stitch condensing 

Pushbutton 3 

Automatic foot lifting at stop in the seam ON / OFF 
 Automatic foot lifting after thread trimming ON / OFF 

Pushbutton 4 

Basic position of the needle (bottom/upper dead center) 
 POSITION 1 / POSITION 2 

 
Pushbutton A 

Pushbutton for backtack suppression and/or recall 

Pushbutton B 

Pushbutton for needle up/down and/or shift button in the programming mode 

 
Symbol C 

Automatic speed is effective 

Symbol D 

Light barrier is on 

Symbol E 

Machine running 

Symbol F 

Limited speed is effective 

Symbol G 

Bobbin thread monitor is on. Symbol blinks when bobbin is empty. 

Summary of Contents for Variocontrol V810

Page 1: ...FRANKL KIRCHNER EFKA OF AMERICA INC EFKA SINGAPORE PTE LTD GMBH CO KG variocontrol CONTROL PANEL V810 V820 INSTRUCTION MANUAL Nr 402205 english...

Page 2: ...el V810 5 7 Operation of Control Panel V810 6 7 1 Programming the Code Number 6 7 2 Selection of the Parameters 6 7 2 1 Direct Selection of the Parameters and Changing Parameter Values 7 7 2 2 Selecti...

Page 3: ...rd Before mounting the control panel and accompanying devices disconnect drive from mains turn off main switch remove mains plug from outlet DIN VDE 0113 part 301 EN 60204 3 1 IEC 204 3 1 Only qualifi...

Page 4: ...nd or V820 according to the instructions of the sewing machine manufacturer before putting the control into service For mounting devices see annex B Attention When choosing the mounting place and when...

Page 5: ...dicated in the programming mode Pushbutton 1 Start backtack SINGLE DOUBLE OFF or start stitch condensing Pushbutton 2 End backtack SINGLE DOUBLE OFF or end stitch condensing Pushbutton 3 Automatic foo...

Page 6: ...blinks Press pushbutton and or to select the second digit Press pushbutton twice Fourth digit blinks Press pushbutton and or to select the fourth digit Press pushbutton E The first parameter on the t...

Page 7: ...button and or to select the third digit Press pushbutton E Parameter value is displayed Press pushbutton and or to select the parameter value After inputting and or changing the parameter value contin...

Page 8: ...level Select the previous parameter by pressing the pushbutton Select the next parameter by pressing the pushbutton After pressing pushbutton E the parameter value is displayed The parameters and or p...

Page 9: ...ER OFF Pushbutton 6 Automatic foot lifting at stop in the seam ON OFF Automatic foot lifting after thread trimming ON OFF Pushbutton 7 Basic position of the needle bottom upper dead center POSITION 1...

Page 10: ...Operation of Control Panel V820 9 1 Code Number Input Code number technician level 1907 and or supplier level 3112 9 2 Selection of the Parameters and Changing Parameter Values After inputting the cod...

Page 11: ...ollowing example possibilities A and B The display varies according to the type of control 9 3 LC Display in the Teach in Mode The following illustration shows the arrangement of symbols of the teach...

Page 12: ...EFKA Variocontrol V810 V820 12 For your notes...

Page 13: ...EFKA Variocontrol V810 V820 13 For your notes...

Page 14: ...EFKA Variocontrol V810 V820 14 For your notes...

Page 15: ......

Page 16: ...115 E Mail info efka net http www efka net OF AMERICA INC 3715 NORTHCREST ROAD SUITE 10 ATLANTA GEORGIA 30340 PHONE 1 770 457 7006 FAX 1 770 458 3899 E mail efkaus bellsouth net EFKA SINGAPORE PTE LTD...

Reviews: