EFKA Variocontrol V810/V820
5
6 Operating Elements of the Control Panel V810
Use insertable strip whose symbols correspond to the type of control. Pull out the standard insertable
strip by using a tool (e.g. tweezers), if necessary, and insert the appropriate strip.
See annex A.
Functional Setting of the Pushbuttons
Pushbutton P
Recall or exit of programming mode
Pushbutton E
Enter button for modifications in the programming mode
Push
Increase of the value indicated in the programming mode
Pushbutton -
Decrease of the value indicated in the programming mode
Pushbutton 1
Start backtack SINGLE / DOUBLE / OFF or start stitch condensing
Pushbutton 2
End backtack SINGLE / DOUBLE / OFF or end stitch condensing
Pushbutton 3
Automatic foot lifting at stop in the seam ON / OFF
Automatic foot lifting after thread trimming ON / OFF
Pushbutton 4
Basic position of the needle (bottom/upper dead center)
POSITION 1 / POSITION 2
Pushbutton A
Pushbutton for backtack suppression and/or recall
Pushbutton B
Pushbutton for needle up/down and/or shift button in the programming mode
Symbol C
Automatic speed is effective
Symbol D
Light barrier is on
Symbol E
Machine running
Symbol F
Limited speed is effective
Symbol G
Bobbin thread monitor is on. Symbol blinks when bobbin is empty.