background image

EFKA Variocontrol V810/V820 

 

 

1  Important Safety Instructions 

 
 
When using the control panel and accompanying devices 
(e.g. for sewing machines), basic safety precautions should 
always be followed, including the following: 

Read all instructions thoroughly before using this 
control panel.  

Control panel and its accessories should be mounted 
and put into operation by qualified personnel in 
accordance with the guidelines provided in the 
instruction manual. 

To reduce the risk of burns, fire, electric shock, or 
personal injury: 

Use this control panel only for its intended use as 
described in the instruction manual. 

Use only attachments recommended by the 
manufacturer or as contained in the instruction 
manual. 

Never operate this control panel if one or more parts 
(e.g. cables, plugs) are damaged, if it is not working 
properly, if any damages can be identified or are to be 
suspected (e.g. after it has been dropped). Only 
qualified personnel are authorized to make 
adjustments, eliminate faults and complete repair 
work. 

Do not use control panel outdoors.  

Do not operate where aerosol (spray) products are 
being used or where oxygen is being administered. 

Do not unplug by pulling on cord. To unplug, grasp 
the plug, not the cord. 

Before mounting the control panel and accompanying 
devices, disconnect drive from mains (turn off main 
switch, remove mains plug from outlet [DIN VDE 
0113 part 301; EN 60204-3-1; IEC 204-3-1]). 

Only qualified personnel are authorized to work on the 
electrical components. 

Work on high voltage circuit areas is forbidden, 
except as stated in the respective regulations, e.g. DIN 
VDE 0105 part 1. 

Only specially trained personnel are authorized to 
complete repair work. 

Cables to be wired must be protected against 
expectable strain and fastened adequately. 

Cables near moving machine parts (e.g. V-belts) must 
be wired at a minimum distance of 25 mm (see DIN 
VDE 0113 part 301; EN 60204-3-1; IEC 204-3-1). 

For safety it is preferred to wire the cables separately 
from each other. 

Observe all safety guidelines before undertaking 
conversions or modifications. 

For repair and maintenance use only original 
replacement parts. 

Warnings in the instruction manual which 
point out particular risks of personal injury or 
risk to the machine are marked with this 
symbol wherever applicable. 

The control panel together with the drive is not an 
independently operating unit, but is designed to be 
incorporated into other machinery. It must not be put 
into service until the machinery into which it is to be 
incorporated has been declared in conformity with the 
provisions of the EC Directive. 

Save these instructions for future reference. 

 

Summary of Contents for Variocontrol V810

Page 1: ...FRANKL KIRCHNER EFKA OF AMERICA INC EFKA SINGAPORE PTE LTD GMBH CO KG variocontrol CONTROL PANEL V810 V820 INSTRUCTION MANUAL Nr 402205 english...

Page 2: ...el V810 5 7 Operation of Control Panel V810 6 7 1 Programming the Code Number 6 7 2 Selection of the Parameters 6 7 2 1 Direct Selection of the Parameters and Changing Parameter Values 7 7 2 2 Selecti...

Page 3: ...rd Before mounting the control panel and accompanying devices disconnect drive from mains turn off main switch remove mains plug from outlet DIN VDE 0113 part 301 EN 60204 3 1 IEC 204 3 1 Only qualifi...

Page 4: ...nd or V820 according to the instructions of the sewing machine manufacturer before putting the control into service For mounting devices see annex B Attention When choosing the mounting place and when...

Page 5: ...dicated in the programming mode Pushbutton 1 Start backtack SINGLE DOUBLE OFF or start stitch condensing Pushbutton 2 End backtack SINGLE DOUBLE OFF or end stitch condensing Pushbutton 3 Automatic foo...

Page 6: ...blinks Press pushbutton and or to select the second digit Press pushbutton twice Fourth digit blinks Press pushbutton and or to select the fourth digit Press pushbutton E The first parameter on the t...

Page 7: ...button and or to select the third digit Press pushbutton E Parameter value is displayed Press pushbutton and or to select the parameter value After inputting and or changing the parameter value contin...

Page 8: ...level Select the previous parameter by pressing the pushbutton Select the next parameter by pressing the pushbutton After pressing pushbutton E the parameter value is displayed The parameters and or p...

Page 9: ...ER OFF Pushbutton 6 Automatic foot lifting at stop in the seam ON OFF Automatic foot lifting after thread trimming ON OFF Pushbutton 7 Basic position of the needle bottom upper dead center POSITION 1...

Page 10: ...Operation of Control Panel V820 9 1 Code Number Input Code number technician level 1907 and or supplier level 3112 9 2 Selection of the Parameters and Changing Parameter Values After inputting the cod...

Page 11: ...ollowing example possibilities A and B The display varies according to the type of control 9 3 LC Display in the Teach in Mode The following illustration shows the arrangement of symbols of the teach...

Page 12: ...EFKA Variocontrol V810 V820 12 For your notes...

Page 13: ...EFKA Variocontrol V810 V820 13 For your notes...

Page 14: ...EFKA Variocontrol V810 V820 14 For your notes...

Page 15: ......

Page 16: ...115 E Mail info efka net http www efka net OF AMERICA INC 3715 NORTHCREST ROAD SUITE 10 ATLANTA GEORGIA 30340 PHONE 1 770 457 7006 FAX 1 770 458 3899 E mail efkaus bellsouth net EFKA SINGAPORE PTE LTD...

Reviews: