EFKA AB60D1472
67
Supplier Level
Code no. 311 with control operation
Parameter
Designation
Unit
max
min
Preset
Ind.
39
=
No
function
40
=
No
function
41
=
No
function
42
=
No
function
43 =
Needle up with subsequent sewing foot lifting
with pedal in pos. 0 (neutral)
44 =
Seam end as with pedal in pos. -2
242 in3
Selection of the input function on socket ST2/6
44 0
0
*) A
and B4/4 for input 3
0 =
No function
All other functions of the keys as with parameter 240
243 in4
Selection of the input function on socket ST2/8
44 0
0
*) A
a
nd B4/5 for input 4
0 =
No function
All other functions of the keys as with parameter 240
250
iFA Thread trimmer activation angle
incr.
120
0
100 *)
A
(1 increment = 1.5°)
251
FSA Switch-off delay of thread tension release
ms
990
0
50 *)
A
252
FSE Switch-on delay of thread tension release
incr.
120
0
0 *)
A
(1 increment = 1.5°)
253
tFA Stop time for thread trimmer
ms
2550 **)
0
70 *)
A
254
tAM Holding power output M1 of the thread trimmer
9
0
2 *)
A
backward (stages 0...9)
Stage 0 = Holding power Off
Stage 1 = 6.25%
Stage 2 = 12.5%
Stage 3 = 18.75%
Stage 4 = 25%
Stage 5 = 31,25%
Stage 6 = 37,5%
Stage 7 = 43,75%
Stage 8 = 50%
Stage 9 = 100% (full power)
263
High lift for walking foot operational mode not stored
1
0
0
A
with input in.. = 13
0 = Signal “high lift for walking foot”, when key is closed.
1 = Signal “high lift for walking foot”, when key is open.
(Function effective if parameter 137 = ON)
266
Limited speed n12 input in.. = 11
1
0
0
A
0 = Speed limitation n12, when key is closed.
1 = Speed limitation n12, when key is open.
273
Trimming function at the start of the seam
ON/OFF
OFF
A
On/Off (only if parameter 290 = 5)
274
Ad1 Delay time of signal M3 at the start of the seam ms
2550 **)
0
40
A
275
At1 ON period of signal M3 at the start of the seam ms
2550 **)
0
150
A
276
Ad2 Delay time of signal M2 at the start of the seam ms
2550 **)
0
50
A
277
At2 ON period of signal M2 at the start of the seam ms
2550 **)
0
60
A
278
Ad3 Delay time of signal M5 at the start of the seam ms
2550 **)
0
40
A
279
At3 ON period of signal M5 at the start of the seam ms
2550 **)
0
350
A
280 kd1
Delay
time
ms
2550
**) 0
0
*) A
281 kt1
ON
period
ms
2550
**) 0
100
*) A
282 kd2
Delay
time
ms
2550
**) 0
100
*) A
283 kt2
ON
period
ms
2550
**) 0
100
*) A
284 kd3
Delay
time
ms
2550
**) 0
200
*) A
285 kt3
ON
period
ms
2550
**) 0
100
*) A
286 kd4
Delay
time
ms
2550
**) 0
300
*) A
287 kt4
ON
period
ms
2550
**) 0
100
*) A
288
kdF Delay time until sewing foot On
ms
2550 **)
0
380 *)
A
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values, the 2-digit or 3-digit value displayed must be
multiplied by 10.