EFKA AB60D1472
65
+
6.4 Supplier
Level
Code no. 311 with control operation
Parameter
Designation
Unit
max
min
Preset
Ind.
201
t2 Sewing foot lift switch-on delay with half
ms
500
20
80 *)
A
heelback
202
t3 Start delay after switching off the sewing foot
ms
500
0
50 *)
A
lift
signal
203
t4 Time of full power of sewing foot lifting
ms
600
0
500 *)
A
204
t5 Holding power for sewing foot lifting
3 *)
A
Stages
0...7
Stage
1
12.5% low holding power
Stage
7
87.5%
Stage
0
100%
high holding power
205
t6 Thread wiper time
ms
2550 **)
0
120 *)
A
206
t7 Delay from end of thread wiper until sewing
ms
800
0
40 *)
A
foot lifting On
207
Braking effect when modifying the preset value
64
1
25
A
≤
4 stages
208
Braking effect when modifying the preset value
64
1
64
A
≥
5 stages
211
tFL Sewing foot lift switch-on delay with thread
ms
500
0
60 *)
A
wiper
off
220
Accelerating power of the drive
255
1
32
A
221
Speed gate 1
RPM
990 **)
50
100
A
222
Speed gate damping period
ms
990
0
0
A
(effective only if parameter 224 = OFF)
223
Speed gate 2
RPM
6500 **)
500
1700
A
224
Speed gate 2 On/Off
ON/OFF
ON
A
231
Execution of the first stitch after Power On
ON/OFF
ON *)
A
at positioning speed
232
Overlock with fast scissors On/Off
ON/OFF
OFF
A
OFF = Tape cutter
ON = Fast scissors (set parameter 282 = 0)
233
Error message A1, if the pedal is not in pos. 0 ON/OFF
ON
A
(neutral), when switching the machine on.
OFF = Error message A1 is suppressed
(e. g. with automats)
ON = Error message A1 is displayed
234
New start after machine run blockage
ON/OFF
ON
A
OFF = New start after deactivating the machine
run blockage without influence by the
pedal (e. g. with automats)
ON = New start after deactivating the machine
run blockage only if pedal in pos. 0
236
0 = Sewing foot lift possible in all positions
2
0
0
A
1 = Sewing foot lift possible in position 2
2 = Sewing foot lift at the seam end stored with pedal
backward. Storing undone with pedal slightly forward.
238
Software debouncing for all inputs:
1
0
1 *)
A
0 = No debouncing
1 = With debouncing
239
FEL Selection of the input function on socket B18/5
44
0
0 *)
A
0 = Light barrier function, if 009 = ON
All other functions as with parameter 240.
Exception is parameter 239 = 14. At this setting,
high lift for walking foot is performed with speed
limitation operational mode not stored.
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values, the 2-digit or 3-digit value displayed must be
multiplied by 10.