![Efka euramot AB60D1472 Manual Download Page 60](http://html1.mh-extra.com/html/efka/euramot-ab60d1472/euramot-ab60d1472_manual_2367394060.webp)
EFKA AB60D1472
62
Technician Level
Code no. 190 with control operation
Parameter
Designation
Unit
max
min
Preset
Ind.
141
Speed status for the seam with stitch counting
3
0
0
A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without influence by
the pedal. Machine stop by pressing the pedal
to the basic position.
2 = Limited speed controllable by the pedal up to the
set speed (parameter 118)
3 = At fixed speed (parameter 118) can be interrupted
by full heelback
142
Speed status for the free seam and for the seam with
3
0
0
A
light
barrier
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 118) without influence by
the pedal. Machine stop by pressing the pedal
to the basic position.
2 = Limited speed controllable by the pedal up to the
set limit (parameter 118)
3 = At fixed speed (parameter 118) can be interrupted
by full heelback (only for seams with light barrier).
143
Stitch counting at the start of the seam
4
0
2 *)
A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 112) without influence by
the pedal. Machine stop by pressing the pedal
to the basic position.
2 = Limited speed controllable by the pedal up to the
set limit (parameter 112)
3 = At fixed speed (parameter 112), can be suspended
or interrupted depending on the setting of
parameter
019.
4 = Limited speed controllable by the pedal up to light
barrier covered. Then fixed speed (parameter 112).
Machine stop by pressing the pedal to the basic
position.
144
Stitch counting at the seam end
4
0
2 *)
A
0 = Speed controllable by the pedal up to the set
maximum speed (parameter 111)
1 = Fixed speed (parameter 113) without influence by
the pedal (machine stop by pressing the pedal
to the basic position)
2 = Limited speed controllable by the pedal up to the
set limit (parameter 113)
3 = At fixed speed (parameter 113), can be suspended
or interrupted depending on the setting of
parameter
019.
4 = At the seam end at light barrier speed without
influence by the pedal. Stop with pedal in pos. 0.
Chain suction at fixed speed (parameter 113) without
influence by the pedal is performed at the seam end
with pedal in pos. –2 until stop.
145
OFF = Signal M1 trimming pos.1...pos.1A
ON/OFF
OFF
A
ON = Signal M1 trimming pos.1...pos.2
(effective only if parameter 290 = 0)
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!