EFKA AB60D1472
61
6.3 Technician
Level
Code no. 190 with control operation
Parameter
Designation
Unit
max
min
Preset
Ind.
100
SSc Number of softstart stitches
stitches
254
0
2 *)
A
110 n1
Positioning
speed
RPM
390 **)
70
200 *) A
111
n2 Upper limit setting range of the maximum speed RPM
9900 **) n2_
4000 *) A
112
n3 Stitch counting speed at the start of the seam
RPM
9900 **) 200
1200 *) A
113
n4 Stitch counting speed at the seam end
RPM
9900 **) 200
1200 *) A
114
n5 Speed after light barrier sensing
RPM
9900 **) 200
1200 A
115 n6
Softstart
speed
RPM 2550
**) 70
500
*) A
116 n7
Trimming
speed
RPM 500
**) 70
200
*) A
117
n10 High lift walking speed
RPM
9900 **)
400
1000 *)
A
118
n12 Automatic speed for stitch counting
RPM
9900 **)
400
3500 *)
A
119
Speed stage graduation
3
1
2 *)
A
1
=
linear
2 = slightly progressive
3 = highly progressive
121
n2_ Lower limit setting range of the maximum speed RPM
n2- **) 400
400 A
122
n9 Limited speed n9
RPM
9900 **) 400
2000 *) A
123
n11 Limited speed n11
RPM
9900 **) 400
2500 *) A
124
Speed limitation by means of ext. potentiometer RPM
9900 **)
Pa.125
4000 *) A
(maximum
value)
125
Speed limitation by means of ext. potentiometer RPM
Pa.124 **) 100
400 *) A
(minimum
value)
Note:
The lower speed will be reached only if
the value of parameter 110
≤
value of parameter
125.
126
Function “speed limitation by means of external
2
0
0 *)
A
potentiometer”
0 = Function “external potentiometer” Off
1 = External potentiometer always active
2 = External potentiometer active only if one of inputs
in1, in3, in4 has been selected and activated
128
Start delay, when command “start” is given by ms
2000 **)
0
0
A
covering the light barrier
(see parameter 129)
129
Machine start by covering the light barrier
ON/OFF
OFF
A
OFF = Function Off
ON = Machine start by covering the light
barrier (only in conjunction with
parameter 132 = ON)
130
Light barrier filter for knitted fabrics
ON/OFF
OFF *)
A
131
OFF = Light barrier sensing “covered”
ON/OFF
ON *)
A
ON = Light barrier sensing “uncovered”
132
OFF = Machine start possible with light barrier ON/OFF
ON *)
A
uncovered or covered.
ON = Machine start blocked with light barrier
uncovered
133
Thread trimming when completing the seam
ON/OFF
ON *)
A
after light barrier sensing On/Off
134
Softstart
On/Off
ON/OFF
OFF
*) A
137
High lift for walking foot / flip-flop 1 On/Off
ON/OFF
ON *)
A
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values, the 2-digit or 3-digit value displayed must be
multiplied by 10.