EFKA AB60D1472
44
Mode 9 (backlatch Yamato) without light barrier
(n9)
ST2/6
in4
ST2/8
/PED
ST2/28
ST2/37
/PED
ST2/21
ST2/35
POS.2
/PED
ST2/27
ST2/32
(LSP)
(n12)
M3
ST2/7
in1
ML
in3
M2
M1
FL
+1
+1
-1
ST2/20
POS.1
+
-
0
n
-2
-1
2
1
/
1
SSc
2
1
0
n2
n6
n12
n1
0 2 5 1 / M O D E- 9
SSc
t3
0 1
n6
2
n2
n9
n1
Mark Function
Parameter
Control
Mode 9
290 = 9
Softstart On
Key S2
Basic position 2
Key S5
in1
Machine run blockage activated with open switch
240 = 6
in3
Automatic speed n12 with open switch
242 = 10
(the function of input 3 is inverted in mode 9)
in4
Automatic speed n9
243 = 34
n1 Positioning
speed
110
n2 Maximum
speed
111
n6 Softstart
speed
115
n9 Automatic
speed
122
n12 Automatic
speed
118
SSc Softstart
stitches
100
t3
Start delay from lifted sewing foot
202
t4
Full power of sewing foot lifting
203
t5
Pulsing of sewing foot lifting
204
*)
With this setting, machine run blockage (safety switch) has priority over automatic speed n12!
**)