EFKA AB60D1472
48
Mode 12 reversal of motor rotation with key in3
ST2/6
ST2/7
in3
t3
ST2/20
ST2/21
ST2/35
POS.2
ST2/37
ST2/28
ST2/27
ST2/32
M2
M3
ML
in1
M1
FL
-
=0
(N.POS)
(ML)
+
POS.1
1
/ 2
-
n
0
-2
-1
1
+
n1
n2
n2
0 25 1/ M O D E- 12
n1
n2
n1
n2
n1
Mark Function
Parameter Control
Mode 12
290 = 12
in1
Key for positioning speed
240 = 20
in3
Key for reversal of motor rotation
242 = 21
n1 Positioning
speed
110
n2 Maximum
speed
111
t3
Start delay from lifted sewing foot
202
M1
Signal “reversal of motor rotation”
M2
Signal “pedal in pos. 0 (neutral)”
M3
Signal “machine running”
Note
The signal ”machine running“ is interrupted for approx. 10ms when pressing the pedal and the key
reversal of motor
rotation.