EFKA AB320A5200
58
6.2 Operator
Level
The preset values of the following list of parameters refer to the setting of parameter 290 = 0.
Parameter
Designation
Unit
max
min
Preset
Ind.
000
c2
- Number of stitches of start backtack forward
stitches
254
0
2
*)
A
- Number of stitches of start stitch condensing
without stitch regulator
- Number of stitches of end counting “chain
suction”
001
c1
- Number of stitches of start backtack backward stitches
254
0
4
*)
A
- Number of stitches of start stitch condensing
with stitch regulator
- Number of stitches of start counting “chain
suction”
002
c3
- Number of stitches of end backtack backward
stitches
254
0
2
*)
A
- Number of stitches of end stitch condensing
with stitch regulator
- Number of stitches of tape cutter at the start
of the seam
003
c4
- Number of stitches of end backtack forward
stitches
254
0
2
*)
A
- Number of stitches of end stitch condensing
without stitch regulator
- Number of stitches of tape cutter at the seam
end
004
LS
Light barrier compensating stitches
stitches
254
0
7
*)
A
005
LSF
Number of stitches of the light barrier filter for
stitches
254
0
1
A
knitted fabrics
006
LSn
Number of light barrier seams
15
1
1
*)
A
007
Stc
Number of stitches for the seam with stitch
stitches
254
0
20
A
counting
008
-F-
A parameter from the technician level is assigned to
5
1
1
*)
A
the 9 key on the V820 control panel
1 = Softstart On/Off
2 = Ornamental backtack On/Off
3 = Sewing start blocked with light barrier uncovered
On/Off
4 = Unlocking the chain On/Off
5 = Signals A1 and/or A2 On/Off with slide-in strips
1...4 (lefthand arrow = A1, righthand arrow = A2)
009
LS
Light barrier On/Off
1
0
0
*)
A
013
FA
Thread trimmer On/Off
1
0
1
*)
A
014
FW
Thread wiper On/Off
1
0
1
*)
A
015
StS
Stitch counting On/Off
1
0
0
A
018
UoS
0 =
Sequence “overlock mode with stop”
3
0
0
A
1 =
Sequence “overlock mode without automatic
stop. When the command “run” is given, the
drive runs at the preselected speed. With
pedal in pos. 0
or
light barrier covered,
the
program switches to the next start of a seam
without issuing signals M1/M2.
2 =
As with setting “1”. But with
pedal in pos. 0
signals M1/M2 will be issued, and the program
switches to the next start of a seam.
3 =
As with setting “1”. But with
pedal in pos. -2
signals M1/M2 will be issued, and the program
switches to the next start of a seam. Inter-
mediate stop and sewing foot lift with
pedal
in pos. –1
are possible.
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!