EFKA AB320A5200
60
6.3 Technician
Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
Parameter
Designation
Unit
max
min
Preset
Ind.
100
SSc
Number of softstart stitches
stitches
254
0
2
*)
A
110
n1
Positioning speed
RPM
390
**)
70
200
*)
A
111
n2-
Upper limit setting range of the maximum speed RPM
9900
**)
n2_
4000
*)
A
112
n3
Start backtacking speed
RPM
9900
**)
200
1200
*)
A
113
n4
End backtacking speed
RPM
9900
**)
200
1200
*)
A
114
n5
Speed after light barrier sensing
RPM
9900
**)
200
1200
A
115
n6
Softstart speed
RPM
1500
**)
70
500
*)
A
116
n7
Trimming speed
RPM
500
**)
70
200
*)
A
117
n10
High lift walking speed
RPM
9900
**)
400
1000
*)
A
118
n12
Automatic speed for stitch counting
RPM
9900
**)
400
3500
*)
A
119
nSt
Speed stage graduation
3
1
2
*)
A
1 = linear
2 = slightly progressive
3 = highly progressive
121
n2_
Lower limit setting range of the maximum speed RPM
n2-
**)
400
400
A
122
n9
Limited speed n9
RPM
9900
**)
400
2000
*)
A
123
n11
Limited speed n11
RPM
9900
**)
400
2500
*)
A
124
toP
Speed limitation by means of ext. potentiometer RPM
9900
**) Pa.125
4000
A
(maximum value)
125
bot
Speed limitation by means of ext. potentiometer RPM
Pa.124
**)
400
400
A
(minimum value)
126
Pot
Function “speed limitation by means of external
2
0
0
A
potentiometer”
0 = Function “external potentiometer” Off
1 = External potentiometer always active
2 = External potentiometer active only if one of
inputs in1...i10 has been selected and enabled
127
AkS
Audible signal of machine run blockage and bobbin
1
0
0
A
thread monitor On/Off
128
Asd
Start delay, when command “start” is given by
ms
2000
**)
0
0
A
covering the light barrier
(see parameter 129)
129
ALS
Machine start by covering the light barrier
3
0
0
A
(only in conjunction with parameter 132 = 1)
0 =
Function Off
1 =
Light barrier covered
!
pedal forward (>1)
!
machine run pedal controlled
2 =
Pedal forward (>1)
!
light barrier covered
!
machine run pedal controlled
3 =
Light barrier covered
!
machine run at
automatic speed n12 (without pedal)
Caution!
If 129 = 3, the machine starts immediately
after covering the light barrier without influence by
the pedal! It can be stopped only by uncovering the
light barrier or by machine run blockage! If machine
run blockage is disabled, the machine starts
immediately even if the light barrier is still covered!
130
LSF
Light barrier filter for knitted fabrics
1
0
0
*)
A
131
LSd
0 =
Light barrier sensing “covered”
1
0
1
*)
A
1 =
Light barrier sensing “uncovered”
132
LSS
0 =
Machine start possible with light barrier
1
0
0
*)
A
uncovered or covered.
1 =
Machine start blocked with light barrier
uncovered if parameter 131 = 1.
Machine start blocked with light barrier
covered if parameter 131 = 0.
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!
**)
When programming the 3-digit or 4-digit control parameter values (without control panel), the 2-digit or 3-digit