Mode 15 (Pegasus SSC100) sequence when high lift for walking foot is Off / start of seam with light barrier
uncovered
Mark
Function
Parameter Control
V810
V820
Mode 15
290 = 15
Tape cutting
On
2 key
4 key
Counts c1 and c2
On
S2/3 key
1 key
1/5 key
Basic position 2
On
S5 key
4 key
7 key
Light barrier
009 = 1
Speed of the light barrier compensating stitches
192 = 1
depending on the pedal
in4
Key for high lift for walking foot operational mode stored
243 = 14
(M6 inverted)
in5
Key for manual tape cutter
244 = 15
n1
Positioning speed
110
n2
Maximum speed
111
c2
Stitch counting until thread tension release Off
000
c1
Stitch counting until thread tension release On
001
LS
Light barrier compensating stitches
004
t3
Start delay from lifted sewing foot
202
t4
Full power of sewing foot lifting
203
t5
Pulsing of sewing foot lifting
204
kdF
Delay time until sewing foot lifting On
288
kt6 *)
Delay time of output VR (chain suction)
256
c7
Start counting until tape cutter M4 On
257
c8
End counting until tape cutter M4 On
258
kt4 *)
ON period of tape cutter M4
287
*)
The value displayed on the control unit must be multiplied by 10.
Example:
The displayed value 10
corresponds to 100ms.
**) Programming is possible at intermediate stop before tape cutting at the start of the seam!
S T2 / 3 5
FL
t3
S T2 / 2 0
S T2 / 2 1
n
P O S.2
P O S.1
+
-
0
- 2
- 1
1
2
1/
n1
n2
n1
LS
n2
3
1
4 5 6 7
t5
t4
kdF
S T2 / 3 2
S T2 / 3 0
S T2 / 8
S T2 / 5
in4
M 6
in5
S T2 / 3 4
S T2 / 2 8
S T2 / 2 7
S T2 / 3 6
S T2 / 3 7
M 5
LS
M 4
VR
M 2
M 3
M 1
(H P )
(AH )
(M L)
(H P )
**)
(AH )
(K S )
(K S )
(FS P L)
(K B )
c7
kt4
kt6
c1
0 2 5 6 / M O D E- 1 5 c
kt4
c8
c2
kt4