Innovating power.
AX M2 Series 3-5 kW | Solar inverter
Troubleshooting & Fault Clearance
–
Page 114
Solar inverter | V1.7
Error code
display
Description
Symbol
60
Back coupling protection
71
Firmware version not compatible
72
Error in current sharing
80
Error in communication bus CAN
81
Connection error
82
Loss of synchronization
83
Battery voltage recognized as different
84
AC input voltage and frequency recognized
as different
85
Asymmetry of the AC output current
86
The setting of the AC input mode is
different
11.2
Pylontech-battery warning messages
Be sure to use the original communication cable supplied with the inverter.
Code
Description
If the battery status cannot be charged and discharged
through successful communication between the inverter
and the battery, the code 60 is displayed to stop the
charging and discharging of the battery.
Communication is interrupted (only available if the battery
type is set to "Pylontech battery").
Once the battery is connected, the communication signal
is not recognized for 3 minutes.
Summary of Contents for AX M2 Series
Page 7: ......
Page 124: ......
Page 131: ...Innovatingpower Technical Data Page 129 Solar inverter V1 7...
Page 132: ......