Installation & User Manual - Sampling Systems
Version 140618 UK
Page 34
8.2
Measurements and parts
A)
SS mounting bracket
B)
Electric actuator
C)
Supply PVC socket 25mm (supply pipe)
D)
Sample drain 20mm hose tail
E)
Flush water drain PVC 25mm socket
F)
Sample tube with 3-piece-coupling
G)
Connector power supply
H)
Connector response contact
8.3
Principle of operation
Check H7.3.
8.4
Installation instructions
Glue the sampler together with PVC-C-glue according fig 8.4a. Glue
according specifications from the glue manufacturer. Be aware, in standby
position the sampler bullet has its cavity pointed to the sample outlet.
A)
Supply pipe (PVC 25/20)
B)
Flush water pipe min 50 mm
C)
Hose tail for sample drain
D)
Bend piece (PVC d25)
E)
Pipe (PVC d25/L68)
F)
Sample pipe (PVC 25/20 /L100) transparent
G)
3-piece coupling (PVC 25/20)
H)
Pipe (PVC 25/20 /L39)
I)
Reduce (PVC 25/20/16)
J)
Collar (PVC 25/20)
K)
Nut (PVC)
Fig. 8.4a
A
B
C
I
D
D
D
L
F
G
J
J
H
H
K
K
A
A
B
B
A
C
D
E
F
G
H
Fig. 8.2a