Installation & User Manual - Sampling Systems
Version 140618 UK
Page 30
7.2
Measurements and parts ILS 3WP SS
A)
Supply pipe fitting Inlet
B)
Mounting bracket
C)
Pillar for sample drain
D)
Pneumatic actuator
E)
Flush water drain
F)
Namur valve
7.3
Operation Principle ILS 3WP SS
The sample cycle of the ILS “3W” sampler works as followed:
•
Standby position
sampler, the sample bullet has its cavity pointed
to the sample outlet.
•
After closure of relay contact K1 (see diagram §1.7) the sample
ball will rotate towards flush position and will stay there as long as
contact K1 is closed. At this point the sample ball makes a passage
between supply inlet and flush outlet:
flush position
.
•
When contact K1 opens, the sample ball will rotate back towards
its rest / drain position. The sampled medium will stay in the
sample pipe.
•
Rest / drain position
and the sample pipe will drain empty.
A
B
E
B
C
D
E
F
Fig.7.3a
Fig. 7.2a