![Edwards STP-301 Series Instruction Manual Download Page 86](http://html.mh-extra.com/html/edwards/stp-301-series/stp-301-series_instruction-manual_2366166086.webp)
9.2
Setting the Rated Speed
The STP pump can be set (changed) to the required rated speed in the range of 25,000 to
48,000 rpm, in units of 500 rpm. The setting can be performed even during rotation of
the STP pump. The rated speed is set to 48,000 rpm at delivery.
The rated speed setting mode is entered by setting dip switch 1 of DSW-B on the top
panel to the ON position.
The rated speed is set to 48,000 rpm (initial setting) by setting dip switch 1 to the OFF
position.
For the position of the DSW-B switch, see Figure 6.3, "STP Control Unit Top Panel."
Prepare the following tool for setting the rated speed:
Small-sized screwdriver
9.2.1
When Setting DSW-B No. 1 to ON under Pow er-ON State
1)
Set dip switch 1 of DSW-B to the ON position.
The LCD displays "SET= ***00rpm," which indicates the rated speed setting mode.
The speed displayed here depends on the current position dialed with the VR1
volume on the top panel.
2)
Turning the VR1 volume on the top panel changes the value "***00rpm" on the
rated speed setting display "SET= ***00rpm."
Turn the VR1 volume clockwise to increase the rated speed, or counterclockwise to
decrease the rated speed, until the required rated speed is displayed.
Note that the rated speed is not yet determined in this state.
3)
To determine the rated speed displayed in "SET= ***00rpm," press the "START"
switch.
When the STP pump is in the ACCELERATION or NORMAL OPERATION state, it
accelerates or decelerates up to the set value of rated speed.
When the STP pump is in the LEVITATION or BRAKE state, the pump's state
remains unchanged.
Note that the rated speed is not determined if the "START" sw itch is pressed w hen the
LCD message is other than "SET= ***00rpm."
4)
Press the "SELECT" switch once, and the LCD displays the set value of rated speed
in "RATING: ***00rpm." Make sure the required rated speed is displayed.
If the required speed is not displayed or the rated speed is to be changed again, press
the "SELECT" switch to display "SET= ***00rpm" again. Then, perform steps 2)
and 3) again to set the rated speed.
5)
When the STP pump is in the LEVITATION or BRAKE state, perform STP pump
rotation operation to rotate it. The STP pump accelerates up to the rated speed.