STP-301/451 Series Instruction Manual
Operation
Table 8.8 shows rated contacts for relays CR4, 5, 6, 7, 8, 9 and 10. (see Figure 8.4)
Table 8.8 Rated Contacts for Relays CR4, 5, 6, 7, 8, 9 and 10
Resistance Load
(cos
φ
=1)
Induction Load
(cos
φ
=0.4)
(L/R=7 ms)
125VAC 0.4A 125VAC 0.2A
Rated Load
30VDC 2A 30VDC 1A
Rated Current
3A
Maximum Contact
Point Voltage
250VAC
220VDC
Maximum Contact
Point Current
3A
Maximum Open/Close
Capacity
AC: 50VA
DC:
60W
AC: 25VA
DC:
30W
Minimum
Applicable Load
DC10mV 10
μ
A
8.3.3
Remote Cables (Optional Accessories)
Remote cables for CON4 are provided as optional accessories.
Remote cables are available in two types: single-side connector type and both-side
connector type. Contact BOC Edwards for details.
Table 8.9 shows connections of remote cables of single-side connector type.
Table 8.9 Remote Cable Connections (Single-Side Connector Type)
Connector
Pin No.
Cable Color
Connector
Pin No.
Cable Color
1
Brown 13
White/Orange
2
Red 14
White/Yellow
3
Orange 15
White/Green
4
Yellow 16
White/Blue
5
Blue 17 Green
6
Purple 18
White/Black/Brown
7
Gray 19
White/Black/Red
8
White 20
White/Black/Orange
9
White/Black 21
White/Black/Yellow
10 White/Brown 22
White/Black/Green
11 White/Red 23
White/Black/Blue
12, hood
Shielded
24
White/Purple, White/Gray