![Edwards STP-301 Series Instruction Manual Download Page 117](http://html.mh-extra.com/html/edwards/stp-301-series/stp-301-series_instruction-manual_2366166117.webp)
STP-301/451 Series Instruction Manual
13-6
Specification
13.2
Specifications of the STP Control Unit
Table 13.2 Specifications of the STP Control Unit
Item Specifications
Input voltage
VAC
100 to 120+/-10% (100V specification)
200 to 240+/-10% (200V specification)
At start:
VA 550
Input power
Under rated operation: VA 150
Input frequency
Hz 50/60 +/-2
Leakage current value
mA 3.5
Input phase
Single phase
Rated current
7.5A
Main
breaker
spec
AIC: Ampere Interrupting
Capacity
1000A (AC240V, 50/60Hz)
Motor drive system
3-phase DC brush-less motor driver
Output voltage under rated
operation (3-phase)
VAC 31 to 62
Output frequency under rated
operation
Hz
420 to 800
Ambient temperature range
°C 0 to 40
Storage temperature range
°C -25 to +55
Mass kg
7
Dimensions
mm W209.5 x H132.5 x D315
Operation switches
[Front Panel]
START switch
(momentary push button, green)
STOP switch
(momentary push button, red)
RESET switch
(momentary push button, white)
SELECT switch
(momentary push button, white)
MANUAL/REMOTE changeover switch
(slide switch, gray)
Panel indication lamps
ACCEL. lamp
(green LED)
NORMAL lamp
(green LED)
BRAKE lamp
(yellow LED)
POWER lamp
(green LED)
FAILURE lamp
(red LED)
REMOTE lamp
(green LED)
Panel display
LCD panel
(16 characters)