10
INPUT/OUTPUT (CODE ‘72’)
‘TB SW-‘ MODE -Mode ‘0’: First impulsion (-0.5 sec) active
magnetization. A long impulsion (+ 0.5 sec)
active the demagnetization. (Toggle switch)
-Mode '1': Gives access to automatic magnet reloading at the
release of sorting. (Momentary push switch)
-Mode ‘2’: A first impulsion (-0.5 sec) activates the
magnetization and a second impulsion (-0.5 sec)
active the demagnetization. (Momentary push switch)
THE ORIGINAL SETTING IS MODE (1)’
‘TB VO’
-hydraulic valve: output activates the hydraulic flow with a
time of 1 to 60 minutes or infinite.
Do not use with an (optional suply).
-Magnet selection uses this for magnet selection after
complete magnet dropping cycle on multiple magnet system
like spreader .Use with optional X BOARD .
THE ORIGINAL SETTING IS 10 MINUTE.
TB IN
To enable or disable TB IN enter access code 102.
To put the parameters ready for new setup
Press for 2 second on the right arrow.
After, with the help of the other two arrows, select ‘0’ and press one time on the right
arrow.