5
14-
If the PWM is too high, it means that the RPM is too low and if the PWM is too
low the RPM is too high.
If you have the possibility to adjust the generator (RPM) EX. hydraulic system. You can activate
the magnet and press and hold the right arrow to see full of (!) on the display. Now at the left you
see the PWM/VOLT in memory and on the right current PWM/VOLT. Adjust the revolution to
have about 750 PWM at right. At the end press once on the right arrow and the right information
will be memorized. After a few seconds the controller will finish its adjustments, and you will be
ready to work.
Controller properties
EDP-C2
is activated by 24 volts manual command instead of traditional 230 volts
therefore making it safer for the operator. It has his own voltage control.
If the wires of the electromagnet disconnect, the controller will automatically lower the
voltage close to 0 volts DC to protect both the operator and the equipment.
The controller will activate the electromagnetic field amperage only when needed to
prevent premature wear of the generator.
The controller may provide two dropping modes and two loading modes ( refer to the
next page )