17
Very dangerous for the controller!!
TROUBLE SHOOTING
Problems frequently encountered:
Cause
Proper voltage is not reached or there is a
bad magnetization - demagnetization
-
Insufficient speed.
-
Belt tension.
-
Bad connections.
-
The generator is too small.
-
Faulty brushes.
Check for faulty fuses
F5,F6,F3,F4
The voltage won’t go over 50volts
-
Check for faulty brushes.
-
Check for faulty fuses.
The voltage is good but there is a lack of
-
Bad connection.
amperage or the magnet doesn’t lift
-
Check the resistance of the
enough material
magnet.
The amperage is to high
-
Check the resistance of
the magnet.
The output voltage is unstable
-
Check if the RPM is too fast.
The demagnetization is not constant
-
Verify the brushes.
-
Insufficient speed
The demagnetization doesn’t occur
-
Check the polarities.
When the magnet is activated,
the letters ‘V’ and ‘A’ should
be written in the same
character size (capital or
lowercase letters) at the same
time of the ‘F’ on the screen.