62
Using the PCR-A30 as a MIDI controller
Advance mode 1, 2
Advanced mode 1 of PROGRAM CHANGE ASSIGN lets you specify the upper and lower limits
of the program change value. Advanced mode 2 lets you transmit BANK LSB/MSB settings in
addition to the program change.
1.
Press the
[EDIT]
button.
2.
Slightly move the controller to which you want to assign a Program Change message. In the case
of a button, press that button. The display will indicate the number of the selected controller.
3.
Confirm what’s indicated, and press the
[ENTER]
button.
Advanced mode 1
—Specifying the range of values
4.
Press the
[PROGRAM CHANGE]
key and then press key
[1]
.
5.
Press the
[ENTER]
button.
6.
Input the channel.
7.
Press the
[ENTER]
button.
8.
Specify the range of values. (
“Specifying the range of values (upper and lower limits)”
Advanced mode 2
—Transmitting bank data
4.
Press the
[PROGRAM CHANGE]
key and then press key
[2]
.
5.
Press the
[ENTER]
button.
6.
Input the channel.
7.
Press the
[ENTER]
button.
fig.bank-2
8.
Specify the bank select MSB (CC#00). Use the
[DEC][INC]
buttons or the
[0]
–
[F]
keys to specify the MSB.
9.
Press the
[ENTER]
button.
fig.l--
10.
10.Specify the bank select LSB (CC#32). Use the
[DEC][INC]
buttons or the
[0]
–
[F]
keys to specify the LSB.
11.
Press the
[ENTER]
button.
12.
Input the program change number.
fig.p
13.
Press the
[ENTER]
button.
The display will indicate “P–”.
14.
Specify the output port. (
➔
*1 Reference
*1 Reference
*1 Reference
*1 The -- area displays the currently set value. If it has not been set, the default setting will be displayed. Even if you change the type or mode
of the MIDI message that is assigned, the default setting will be displayed. This will be lit if the value is the same as the currently set value,
or will blink if the value is different.
PCR-A30_e2.book 62 ページ 2003年10月22日 水曜日 午後3時19分