- 32
-
ENGLISH
SYSTEM FOR AN OPEN TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACEITH HOT SANITARY WATER PRO-
DUCTION AND A WALL MOUNTED BOILER USING
KIT N3
CA:
Wall Mounted Boiler
PR:
Pump (circulator)
P1:
Primary circuit pump
RE:
Electronic regulator
TA:
Room thermostat
VE:
Expansion Tank
Ja:
Air re
Ŏ
ef Valve
V:
Intercept valve
VR:
Retaining valve
ST:
Temperature Sensor
F:
Flow switch
Sc:
Heat plate exchanger
EV:
3-way solenoid valve
RI:
Heating system return
RA:
Radiators
MI:
Heating system
ŏ
ow
AF:
Cold water
ACS:
Hot sanitary water
S:
Drain
KIT N3 code 627690
1. Heating
system
ŏ
ow G 3
”
2. EDILKAMIN
generator
ŏ
ow G 3
”
3.
EDILKAMIN generator return G 3
”
.
Heating system return G 3
”
5.
Cold sanitary water inlet G 1
2”
6.
Hot water return to the sanitary system G 1
2”
7.
Safety valve - temperature and pressure (90
°C - 3bar)
8. Flow
Switch
9.
Air relief valve G 3
8”
10. EDILKAMIN generator circuit circulator
11. 3-way heat exchanger
12. Intercept valve G 1”
13. Electronic regulator with wiring
1
. Appropriate aperture for the cable duct to pass
through
15. Power
cable
16. Cables for the heating system circulator (phase,
neutral, earth)
17. Temperature
sensor
18. Room thermostat circuit
VE
AF
S
V
RE
RETE
ST
V
S
V
T
ubo
di
carico
Ø>
18
mm
T
ubo
di
sicurezza
Ø>
28
mm
V
CA
ACS
PR
F
ACS
AF
Ja
TA
P1
V
Vs
Sc
TCN
ELETTRICA
INT
VR
V
VR
RETE
IDRICA
VR
VR
MI
RA
RI
V
COLLETTORE
VR
V
V
V
V
V
Circuito collegabile al
termostato ambiente
(a discrezione del cliente)
Da collegare
necessariamente
al circolatore dell’impianto
di riscaldamento
PR
1
2
3
4
5
6
7
8
9
10
11
9
9
12
13
1
2
3
5
4
6
7
14
15
16 17
Passacavi
18
Primary cir-
cuit pump
OFF
Primary circulator
enabled setting
30-
0°C
ON
Heating pump
EV
Electricity
Mains 230 Vac
50 Hz +
- 10%
Sanitary-heating enabled
setting
0-80°C
Room
thermostat
Flow sensor
sensor
Enabled
alarm
Electrical Connections
Safety pipe Ø> 28mm
Inlet pipe Ø> 18mm
circuit connected
to the room
thermostat
(implemented by
the client)
must be connected
to the heating system
circulator
Water
Mains
Collector
Electricity
Mains
Kit N3 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the
product to be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted
E\WKHWKHUPRŎUHSODFH
Cable duct
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY