- 24
-
ENGLISH
TECHNICALAND HEATING SPECIFICATIONS
N.B.: DATA PROJECT (Refer to standard EN 13229)
*
The heatable room dimensions are calculated on the basis home insulation in compliance with Italian law 10
91, and subsequent
changes together with an expected heat output of 33 Kcal
m
t
per hour.
* It is also important to consider the position of the boiler-
Ŏ
replace in the room to be heated.
* * boiler temperature is 70° - (ðT=25K)
The data shown above is purely indicative.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THIS TO FUNCTION PROPERLY
THE DIAMETER OF THE CHIMNEY FLUE TO BE USED MUST BE ASSESSED BY THE INSTALLER ACCOR-
DING TO THE HEIGHT OF THE CHIMNEY FLUE ITSELF.
15-15/CS
23-23/CS
28-28/CS
Thermal output (burnt)
18,5
27,8
3
,8
kW
Rated power
1
,8
22,2
27,8
kW
Water heating power
12,1
18,2
22,8
kW
Approx. overall ef
Ŏ
ciency
80
80
80
%
Approx. water ef
Ŏ
ciency
82
82
82
%
Class ef
Ŏ
ciency (EN 303-5)
> 3
> 3
> 3
-
ø female smoke outlet
18
22
25
cm
Maximum operating pressure
1,5
1,5
1,5
bar
Fuel consumption
,5
7
8,5
kg
h
Water capacity
50
100
130
litres
Heating capacity *
355
535
670
m
t
Weight including packing
2
0
285
325
kg
Hot sanitary water production (kit 1- 3 - N3 - N3bis)**
13-1
13-1
13-1
litres
min
ø external air inlet
12,5
12,5
12,5
cm
System return (male)
1”
1”
1”
inches
System
ŏ
ow (male)
1”
1”
1”
inches