6-13
6.2.2
O-ring Considerations
The PORT-LF’s End Cap assemblies use a standard O-ring to provide watertight integrity to the Electronics
Housing. Under normal usage, proper care, and lubrication, the O-ring should provide several years of
usage. However, like the batteries, the O-ring is an inexpensive component, which is absolutely critical to
the successful operation of the entire system. Depending on the frequency of use, it is a good practice to
periodically replace the O-ring. It is essential to inspect the O-rings and sealing surfaces before and after
each deployment.
Prepare the sealing surfaces for assembly by cleaning with a lint-free towel or swab, moistened (if needed)
with alcohol. Inspect for scratches or nicks which could impair the O-ring’s ability to provide a seal. Apply
a light coat of O-ring lubricant (EdgeTech recommends Parker’s Super O-lube, be sure to use only silicone
grease) to the Housing and O-ring to facilitate insertion of the end cap. Make sure the lubricant is
compatible with Nitrile rubber. Inspect the O-ring for damage such as tears, dimples, or other defects in
the rubber. Replace any O-ring that is questionable or old. Lightly coat the O-ring with lubricant. Protect
O-rings when stretching them over large diameters.
CAUTION
Applying too much lubricant to the O-ring can compromise the seal.
6.2.3
Additional O-rings
There are additional O-rings that provide the watertight integrity to the Housing. These are located on the
purge port and release shaft. Check and replace these O-rings periodically as well.
6.2.4
O-ring Service Disassembly
1.
Remove the Purge Port Plug, referring to sub-section
2.
Remove the Release End, referring to sub-section
. (Do not go to step 4.1.3)
3.
When you open the Release End
,
slide the electronics assembly out just enough to disconnect the
Transducer Cable from (JP1), as shown in
Figure 6-20: The Transducer Cable Connected to the Electronics Board
Summary of Contents for PORT LF
Page 9: ...ix 6 Fax one invoice packing list and a copy of the airway bill to EdgeTech upon shipment...
Page 18: ......
Page 20: ......
Page 25: ...2 5 Figure 2 2 PORT LF Mechanical Standard 0010815...
Page 26: ...SECTION 2 SPECIFICATIONS 2 6 Figure 2 3 PORT LF DEEP Mechanical 0019564...
Page 46: ......
Page 48: ......
Page 65: ...6 17 Figure 6 24 PORT LF Callout Assembly Drawing Page 1 of 2 0008118...
Page 66: ...MAINTENANCE 6 18 Figure 6 25 PORT LF Callout Assembly Drawing Page 2 of 2 0008118...
Page 69: ......
Page 70: ...REMOTE RELEASE B 2 Appendix Figure B 1 Remote Release 0012120...
Page 71: ...B 3 Appendix Figure B 2 PORT LF Optional Remote Release 0012266...
Page 72: ...B 4 Appendix Figure B 3 PORT LF Optional Remote Release Callout 0007639...
Page 74: ...C 2 Appendix Figure C 1 Optional Tandem Kit Diagram 0017625...
Page 75: ...C 3 Appendix Figure C 2 PORT LF Optional Tandem Kit Callout Diagram 0008237...
Page 76: ......
Page 78: ...D 2 Appendix Figure D 1 PORT LF Optional Strongback Diagram 0017674...
Page 79: ...D 3 Appendix Figure D 2 PORT LF Optional Strongback Kit Callout Diagram 0008166...