System Management Commands
4-35
4
databits
This command sets the number of data bits per character that are interpreted and
generated by the console port. Use the
no
form to restore the default value.
Syntax
databits
{
7
|
8
}
no databits
• 7 - Seven data bits per character.
• 8 - Eight data bits per character.
Default Setting
8 data bits per character
Command Mode
Line Configuration
Command Usage
The
databits
command can be used to mask the high bit on input from
devices that generate 7 data bits with parity. If parity is being generated,
specify 7 data bits per character. If no parity is required, specify 8 data bits per
character.
Example
To specify 7 data bits, enter this command:
Related Commands
parity
This command defines the generation of a parity bit. Use the
no
form to restore the
default setting.
Syntax
parity
{
none
|
even
|
odd
}
no parity
•
none
- No parity
•
even
- Even parity
•
odd
- Odd parity
Default Setting
No parity
Command Mode
Line Configuration