C
HAPTER
41
| CFM Commands
Defining CFM Structures
– 1326 –
pass, and only if a maintenance end point (MEP) is created at
some lower MA Level.
none
– No MIP can be created for any MA configured in this
domain.
D
EFAULT
S
ETTING
No maintenance domains are configured.
No MIPs are created for any MA in the specified domain.
C
OMMAND
M
ODE
Global Configuration
C
OMMAND
U
SAGE
◆
A domain can only be configured with one name.
◆
Where domains are nested, an upper-level hierarchical domain must
have a higher maintenance level than the ones it encompasses. The
higher to lower level domain types commonly include entities such as
customer, service provider, and operator.
◆
More than one domain can be configured at the same maintenance
level, but a single domain can only be configured with one maintenance
level.
◆
If MEPs or MAs are configured for a domain using the
ethernet cfm mep
command or
ma index name
command, they must first be removed
before you can remove the domain.
◆
Maintenance domains are designed to provide a transparent method of
verifying and resolving connectivity problems for end-to-end
connections. By default, these connections run between the domain
service access points (DSAPs) within each MA defined for a domain,
and are manually configured using the
ethernet cfm mep
command.
In contrast, MIPs are interconnection points that make up all possible
paths between the DSAPs within an MA. MIPs are automatically
generated by the CFM protocol when the
mip-creation
option in this
command is set to “default” or “explicit,” and the MIP creation state
machine is invoked (as defined in IEEE 802.1ag). The default option
allows MIPs to be created for all interconnection points within an MA,
regardless of the domain’s level in the maintenance hierarchy (e.g.,
customer, provider, or operator). While the explicit option only
generates MIPs within an MA if its associated domain is not at the
bottom of the maintenance hierarchy. This option is used to hide the
structure of network at the lowest domain level.
The diagnostic functions provided by CFM can be used to detect
connectivity failures between any pair of MEPs in an MA. Using MIPs
allows these failures to be isolated to smaller segments of the network.
Allowing the CFM to generate MIPs exposes more of the network
structure to users at higher domain levels, but can speed up the
process of fault detection and recovery. This trade-off should be
carefully considered when designing a CFM maintenance structure.
Summary of Contents for ES3528MV2
Page 1: ...Management Guide www edge core com ES3528MV2 ES3528MV2 DC 28 Port Fast Ethernet Layer 2 Switch...
Page 2: ......
Page 4: ......
Page 48: ...CONTENTS 48...
Page 68: ...SECTION I Getting Started 68...
Page 78: ...CHAPTER 1 Introduction System Defaults 78...
Page 96: ...SECTION II Web Configuration 96...
Page 116: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 116...
Page 148: ...CHAPTER 4 Basic Management Tasks Resetting the System 148...
Page 192: ...CHAPTER 5 Interface Configuration VLAN Trunking 192 Figure 65 Configuring VLAN Trunking...
Page 226: ...CHAPTER 6 VLAN Configuration Configuring VLAN Translation 226...
Page 236: ...CHAPTER 7 Address Table Settings Configuring MAC Address Mirroring 236...
Page 270: ...CHAPTER 9 Congestion Control Automatic Traffic Control 270...
Page 300: ...CHAPTER 11 Quality of Service Attaching a Policy Map to a Port 300...
Page 418: ...CHAPTER 13 Security Measures DHCP Snooping 418...
Page 588: ...CHAPTER 15 IP Configuration Setting the Switch s IP Address IP Version 6 588...
Page 606: ...CHAPTER 16 IP Services Configuring the PPPoE Intermediate Agent 606...
Page 676: ...CHAPTER 17 Multicast Filtering Multicast VLAN Registration for IPv6 676...
Page 772: ...CHAPTER 20 System Management Commands Switch Clustering 772...
Page 802: ...CHAPTER 22 Remote Monitoring Commands 802...
Page 808: ...CHAPTER 23 Flow Sampling Commands 808...
Page 872: ...CHAPTER 24 Authentication Commands PPPoE Intermediate Agent 872...
Page 950: ...CHAPTER 25 General Security Measures Port based Traffic Segmentation 950...
Page 1002: ...CHAPTER 27 Interface Commands Power Savings 1002...
Page 1016: ...CHAPTER 28 Link Aggregation Commands Trunk Status Display Commands 1016...
Page 1046: ...CHAPTER 30 Congestion Control Commands Automatic Traffic Control Commands 1046...
Page 1058: ...CHAPTER 32 UniDirectional Link Detection Commands 1058...
Page 1064: ...CHAPTER 33 Address Table Commands 1064...
Page 1124: ...CHAPTER 35 ERPS Commands 1124...
Page 1168: ...CHAPTER 36 VLAN Commands Configuring Voice VLANs 1168...
Page 1182: ...CHAPTER 37 Class of Service Commands Priority Commands Layer 3 and 4 1182...
Page 1202: ...CHAPTER 38 Quality of Service Commands 1202...
Page 1360: ...CHAPTER 41 CFM Commands Delay Measure Operations 1360...
Page 1382: ...CHAPTER 43 Domain Name Service Commands 1382...
Page 1440: ...SECTION IV Appendices 1440...
Page 1468: ...COMMAND LIST 1468...
Page 1479: ......
Page 1480: ...ES3528MV2 ES3528MV2 DC E112013 ST R03...